2023
DOI: 10.1016/j.fluid.2022.113572
|View full text |Cite
|
Sign up to set email alerts
|

Carbon dioxide solubility in ionic liquids: [Guad-(6,6),(1,1),(1,1)][DCA] and [Guad-(6,6),(1,1),(1,1)][TCM] at high pressure

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3

Relationship

2
1

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 49 publications
0
3
0
Order By: Relevance
“…The reliability of the static synthetic isothermal (SynT) apparatus and the experimental procedure employed to measure the solubility of methane and ethane, which are sparingly soluble gases in sweetening solvents, was demonstrated in our previous work . Detailed descriptions of the apparatus and experimental procedure can be found in previous works. ,, The apparatus has a transparent equilibrium cell made from a sapphire tube and two stainless steel flanges with a capacity of 36.29 cm 3 . To monitor the temperature and pressure within the cell, two 100 Ω platinum resistance (Pt-100) probes (WIKA; 1/10 DIN) and a pressure transmitter (WIKA; P-30; 4 MPa) were utilized.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The reliability of the static synthetic isothermal (SynT) apparatus and the experimental procedure employed to measure the solubility of methane and ethane, which are sparingly soluble gases in sweetening solvents, was demonstrated in our previous work . Detailed descriptions of the apparatus and experimental procedure can be found in previous works. ,, The apparatus has a transparent equilibrium cell made from a sapphire tube and two stainless steel flanges with a capacity of 36.29 cm 3 . To monitor the temperature and pressure within the cell, two 100 Ω platinum resistance (Pt-100) probes (WIKA; 1/10 DIN) and a pressure transmitter (WIKA; P-30; 4 MPa) were utilized.…”
Section: Methodsmentioning
confidence: 99%
“…31 Detailed descriptions of the apparatus and experimental procedure can be found in previous works. 1,33,34 The apparatus has a transparent equilibrium cell made from a sapphire tube and two stainless steel flanges with a capacity of 36.29 cm 3 . To monitor the temperature and pressure within the cell, two 100 Ω platinum resistance (Pt-100) probes (WIKA; 1/10 DIN) and a pressure transmitter (WIKA; P-30; 4 MPa) were utilized.…”
Section: Introductionmentioning
confidence: 99%
“…The solubility of methane and ethane in the hybrid solvents was measured using a static synthetic isothermal (SynVis) apparatus. The apparatus and experimental procedure were described in detail in previous works. ,, A transparent equilibrium cell with a capacity of 36.29 cm 3 and constructed from a sapphire tube is the core of the apparatus. The cell was submerged into a temperature-regulated water bath to control temperature.…”
Section: Methodsmentioning
confidence: 99%