2022
DOI: 10.1016/j.aca.2022.340477
|View full text |Cite
|
Sign up to set email alerts
|

Carbon fiber paper spray ionization mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 9 publications
(3 citation statements)
references
References 47 publications
0
3
0
Order By: Relevance
“…A layer of MWCNTs was coated on the paper surface, which acted as an electrode to induce a stable electric field, which was expected to play a key role in the ionization of target analytes. The effect of atmospheric pressure chemical ionization is similar to carbon fiber PSI 53 and carbon fiber ionization 54 described earlier. Experimental results revealed that the fabrication of paper substrates by MWCNTs could lead to enhancement in signal intensities by 20–50 times and 2–4 times for PAHs and PFCs, respectively, compared to unmodified paper substrates (Figures S3–S5 [supporting information]).…”
Section: Resultsmentioning
confidence: 67%
See 1 more Smart Citation
“…A layer of MWCNTs was coated on the paper surface, which acted as an electrode to induce a stable electric field, which was expected to play a key role in the ionization of target analytes. The effect of atmospheric pressure chemical ionization is similar to carbon fiber PSI 53 and carbon fiber ionization 54 described earlier. Experimental results revealed that the fabrication of paper substrates by MWCNTs could lead to enhancement in signal intensities by 20–50 times and 2–4 times for PAHs and PFCs, respectively, compared to unmodified paper substrates (Figures S3–S5 [supporting information]).…”
Section: Resultsmentioning
confidence: 67%
“…The effect of atmospheric pressure chemical ionization is similar to carbon fiber PSI 53 and carbon fiber ionization 54 The recovery was evaluated by spiking blank samples with appropriate amounts of the analytes at three levels corresponding to LOQs, 10-fold LOQs, and 20-fold LOQs. The average recovery rates varied from 93.1% to 105.8%, with relative standard deviations (RSDs) of 3.5%-10.3% for six repeated measurements.…”
Section: Optimization Of Psi and Miniature Ms Conditionsmentioning
confidence: 99%
“…each respectively coupled PS‐MS with a flexible microtube plasma and atmospheric pressure photoionization to facilitate the ionization of less polar analytes, Wang et al. used carbon fibre as the PS substrate to enhance sensitivity and signal stability, 181 whereas Martínez‐Jarquín et al. introduced an aptamer‐functionalized paper substrate for the concentration and detection of small molecules 182 …”
Section: Applications Of Aimsmentioning
confidence: 99%