2021
DOI: 10.1016/j.energy.2021.120459
|View full text |Cite
|
Sign up to set email alerts
|

Carbon nanotube sheet as a microporous layer for proton exchange membrane fuel cells

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
26
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 34 publications
(26 citation statements)
references
References 48 publications
0
26
0
Order By: Relevance
“…Compared to GDL, the high‐BET surface area (89.05 m 2 /g), small pores (2‐70 nm), and high porosity (83%) allow the reactants to diffuse uniformly. This increases the reaction area of the catalyst and reduces R ct 34,36 . In the 100% RH condition of MEA with CDL, the convex shape ( R mt ) of EIS is confirmed in the low‐frequency region, because excessive water stagnation interfered with the drive of the reactants.…”
Section: Resultsmentioning
confidence: 93%
See 2 more Smart Citations
“…Compared to GDL, the high‐BET surface area (89.05 m 2 /g), small pores (2‐70 nm), and high porosity (83%) allow the reactants to diffuse uniformly. This increases the reaction area of the catalyst and reduces R ct 34,36 . In the 100% RH condition of MEA with CDL, the convex shape ( R mt ) of EIS is confirmed in the low‐frequency region, because excessive water stagnation interfered with the drive of the reactants.…”
Section: Resultsmentioning
confidence: 93%
“…Consequently, it leads to hydration of the membrane 33‐35 . Second, the nanostructure facilitates the uniform dispersion of the reactants 27,36 . The pore size range of the CDL was 2‐70 nm, as shown in Figure 2D.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The measurement of 0.96 V using a 1.46 umthick Ag current collecting layer cell was relatively lower than other OCVs. However, a number of prior studies showed around 1.0 V of OCVs [2,3,[5][6][7][16][17][18][19][20]. This is because of the inherent hydrogen permeability of Nafion ® , PTFE gaskets, etc.…”
Section: Resultsmentioning
confidence: 98%
“…The same composition of ink has been used elsewhere. 33,34 The mixed elements were sonicated for 60 min. Only one ink was prepared for each cell; for example, the ink for Cell 2 is diluted with each cycle (some of the solid components are deposited on the membrane or GDL) and recycled for subsequent cycles.…”
Section: Methodsmentioning
confidence: 99%