Carbon Nanotubes as a Low Background Signal Platform for a Molecular Aptamer Beacon on the Basis of Long-Range Resonance Energy Transfer

Abstract: Although holding the advantages of both an aptamer and a molecular beacon (MB), a molecular aptamer beacon (MAB) needs complicated and expensive modifications at both of its ends and usually has a high background signal because of the low energy transfer efficiency between the donor and the acceptor. To overcome these shortcomings, in this study, we develop a long-range resonance energy transfer (LrRET) system by separating the donor from the acceptor, wherein only one end of the MAB is fluorescently labeled a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
51
0

Year Published

2012
2012
2019
2019

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 101 publications
(52 citation statements)
references
References 37 publications
1
51
0
Order By: Relevance
“…The linear detection range with FA measurement was from 0.5 μM to 20 μM (y = 0.220-0.004x, R 2 = 0.990; y is FA value). The sensitivity of this competitive aptamer FA assay is comparable to those of aptamer FA assays [10,13,15,[29][30][31], and it is also comparable to that of some other aptamer-based assays for ATP with different detection methods [21,32,33]. The generated maximum FA/FP change in our method is much higher than that of some aptamer FA assays [15,[29][30][31].…”
Section: Competitive Fa Assay For Atpsupporting
confidence: 65%
“…The linear detection range with FA measurement was from 0.5 μM to 20 μM (y = 0.220-0.004x, R 2 = 0.990; y is FA value). The sensitivity of this competitive aptamer FA assay is comparable to those of aptamer FA assays [10,13,15,[29][30][31], and it is also comparable to that of some other aptamer-based assays for ATP with different detection methods [21,32,33]. The generated maximum FA/FP change in our method is much higher than that of some aptamer FA assays [15,[29][30][31].…”
Section: Competitive Fa Assay For Atpsupporting
confidence: 65%
“…This designed system provides a sensitive method for the detection of ATP, with better sensitivity than many aptamer-based biosensing systems (He et al 2011;S. Zhang et al 2009;J. Zhen et al 2010) (limits of detection vary from 0.11 mM to 10 mM) and is comparable with some enzyme-based amplification systems (Li, Fu et al 2012;) (limits of detection are 0.1 mM and 10 mM, respectively).…”
Section: Sensitivity and Selectivitymentioning
confidence: 96%
“…Recently, a molecular aptamer beacon (MAB), an MB-based oligonucleotide probe having a target-specific aptamer sequence in the loop part, was found to probe its target with high specificity. 10 As an application of conventional MABs, single fluorophore labeled MAB systems were reported, in which multi-walled carbon nanotubes (MWCNTs) 11 or GOs 12 act as a quencher.…”
Section: Introductionmentioning
confidence: 99%