The use of magnetic fields in the intermediate-frequency (IF) range to wirelessly charge electric cars with power transfer in the kilowatt range has become increasingly widespread, leading to unavoidable stray fields in the microtesla range. Only a handful of studies have assessed the potential biological risks associated with exposure to such fields. We exposed female mice (n = 80 per group) to either 20 kHz, 360 μT (rms), or sham in Helmholtz coils to conduct a blind design study. Exposure started at 3 months of age (24 h/day). Body mass was recorded every 1-2 weeks. At 10 months of age, three behavioral tests were performed on 24 animals per group. Three months later, the mice were sacrificed and organs (brain, liver, kidney, spleen, and lung) were removed and prepared for microscopic analysis. Our findings demonstrate no differences in the development of body mass and survival rates (96% and 89%, respectively). Similarly, no significant differences were observed in tumor incidence rates. When it comes to behavioral tests, the 8-arm maze results revealed no significant differences. In contrast, the Rotarod data were significantly (P < 0.001) different with longer retention times seen in the exposed mice. In the open field, the number of supported rears was significantly lower (P < 0.01), whereas the other endpoints did not show any differences. Overall, our data reveal no adverse effects of exposure to 20 kHz, 360 μT on the development and tumor incidences, while the significant differences in the behavioral tests may indicate higher levels of alertness in mice.