Cardiac Magnetic Resonance Imaging Using an Open 0.35 T System

Abstract: Open MRI with lower field strength can be used for functional imaging of the heart. For perfusion and viability imaging (late enhancement), higher field strength is needed. Open low-field cardiac MRI may provide a helpful alternative for obese or claustrophobic patients or patients who are difficult to move.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
18
0

Year Published

2008
2008
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 16 publications
(18 citation statements)
references
References 10 publications
0
18
0
Order By: Relevance
“…An open scanner configuration might impair image quality due to a potentially larger inhomogeneity of a vertical magnetic field. Moreover, until recently, such systems operated at rather low field strengths [11], [12], [13]. However, there is no study directly comparing the image quality of horizontal and vertical magnetic field MR systems.…”
Section: Introductionmentioning
confidence: 99%
“…An open scanner configuration might impair image quality due to a potentially larger inhomogeneity of a vertical magnetic field. Moreover, until recently, such systems operated at rather low field strengths [11], [12], [13]. However, there is no study directly comparing the image quality of horizontal and vertical magnetic field MR systems.…”
Section: Introductionmentioning
confidence: 99%
“…Standard bore magnets have aperture diameters of 60 cm with a table weight limit of 159 kg (Table 3) provide anatomic information about the heart, for perfusion or functional studies, higher field strengths were needed [36]. Weaker gradients of open MRI systems result in reduced signal-tonoise ratio (SNR).…”
Section: Magnetic Resonance Imagingmentioning
confidence: 99%
“…However, it should first be considered whether the SNR available at lower field may be sufficient to generate diagnostic quality CMR images 14 , especially when bSSFP based pulse sequences and compressed sensing (CS) inspired image recovery methods are employed. Figure 1 shows the degradation in the quality of a segmented bSSFP cine series acquired at 1.5T when the SNR is retrospectively reduced by adding noise to the measured k-space data to simulate the impact of reduced field strength on SNR alone.…”
Section: The Technical Aspects Of Cmr At Low Fieldmentioning
confidence: 99%