2018
DOI: 10.1093/ejcts/ezy399
|View full text |Cite
|
Sign up to set email alerts
|

Cardiac remodelling following thoracic endovascular aortic repair for descending aortic aneurysms

Abstract: OBJECTIVES Current endografts for thoracic endovascular aortic repair (TEVAR) are much stiffer than the aorta and have been shown to induce acute stiffening. In this study, we aimed to estimate the impact of TEVAR on left ventricular (LV) stroke work (SW) and mass using a non-invasive image-based workflow. METHODS The University of Michigan database was searched for patients treated with TEVAR for descending aortic pathologie… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

1
43
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 74 publications
(44 citation statements)
references
References 30 publications
1
43
0
Order By: Relevance
“…engineering fields that can be applied to study complex flow dynamics. Image-based computational tools have been developed for cardiovascular disease research, 24,25 medical device evaluation and, more recently, virtual planning of surgical interventions. 9 An unexpected finding of this investigation was that most surgical repairs resulted in a reduction in renal artery pressures (Figure 8).…”
Section: Computational Modeling Computational Modeling Is a Widely Umentioning
confidence: 99%
“…engineering fields that can be applied to study complex flow dynamics. Image-based computational tools have been developed for cardiovascular disease research, 24,25 medical device evaluation and, more recently, virtual planning of surgical interventions. 9 An unexpected finding of this investigation was that most surgical repairs resulted in a reduction in renal artery pressures (Figure 8).…”
Section: Computational Modeling Computational Modeling Is a Widely Umentioning
confidence: 99%
“…This increased stiffness of the aorta following stent-graft deployment can increase stresses in the untreated segments of the aortic wall (28). Furthermore, left ventricular stroke work is estimated to increase up to 26% as a consequence of stent-graft induced descending aortic stiffening, resulting in adverse left ventricular remodeling (29).…”
Section: Tevar Challengesmentioning
confidence: 99%
“…However, trepidation about the long-term effect of extensive aortic coverage on cardiac function has justifiably raised concerns among vascular communities. 12 These apprehensions have encouraged pioneering techniques to reduce aortic coverage while simultaneously promoting remodeling of the entire aorta and maintaining side branch perfusion. The determination to lessen aortic coverage and preserve compliance has been achieved using the s t aged h ybrid sin g le lum e n r econstruction (TIGER) technique.…”
mentioning
confidence: 99%
“…The MFM is not a resolution for patients living on borrowed time and must not be used erratically in those patients in whom other modus operandi of aortic repair are not achievable. 1014…”
mentioning
confidence: 99%
See 1 more Smart Citation