2013
DOI: 10.1186/1532-429x-15-59
|View full text |Cite
|
Sign up to set email alerts
|

Cardiac-respiratory self-gated cine ultra-short echo time (UTE) cardiovascular magnetic resonance for assessment of functional cardiac parameters at high magnetic fields

Abstract: BackgroundTo overcome flow and electrocardiogram-trigger artifacts in cardiovascular magnetic resonance (CMR), we have implemented a cardiac and respiratory self-gated cine ultra-short echo time (UTE) sequence. We have assessed its performance in healthy mice by comparing the results with those obtained with a self-gated cine fast low angle shot (FLASH) sequence and with echocardiography.Methods2D self-gated cine UTE (TE/TR = 314 μs/6.2 ms, resolution: 129 × 129 μm, scan time per slice: 5 min 5 sec) and self-g… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
31
0

Year Published

2014
2014
2017
2017

Publication Types

Select...
7
2
1

Relationship

1
9

Authors

Journals

citations
Cited by 37 publications
(31 citation statements)
references
References 44 publications
(38 reference statements)
0
31
0
Order By: Relevance
“…Because at HF ECG signal is often degraded by the magnetohydrodynamic effects, RF pulses, and gradient switching during scanning [53], alternative techniques to the classical gating have been reported for rodents, using optimized gating strategies with cardiorespiratory monitoring [6,33] or complete monitoring-free approaches [63][64][65]103]. Optimized approaches developed to speed up image acquisitions are developed in ''Improving imaging speed: parallel imaging, compressed sensing (CS) and cryoprobes''.…”
Section: Animal Handling and Gating Strategiesmentioning
confidence: 99%
“…Because at HF ECG signal is often degraded by the magnetohydrodynamic effects, RF pulses, and gradient switching during scanning [53], alternative techniques to the classical gating have been reported for rodents, using optimized gating strategies with cardiorespiratory monitoring [6,33] or complete monitoring-free approaches [63][64][65]103]. Optimized approaches developed to speed up image acquisitions are developed in ''Improving imaging speed: parallel imaging, compressed sensing (CS) and cryoprobes''.…”
Section: Animal Handling and Gating Strategiesmentioning
confidence: 99%
“…The basic idea of self-gating is extracting the information of cardiac cycle from the k-space measurements without extra operators or equipment [5]. Some researcher are working on the respiratory self-gated research [6] [7] [8].…”
Section: Instructionmentioning
confidence: 99%
“…Ultrashort echo time (UTE) imaging of very short T2 components in tissues may allow detection of fibrosis and calcification in the myocardium and atherosclerotic plaques [176][177][178]. Stress perfusion imaging may also be combined with arterial spin labeling (ASL), or mapping techniques in addition to BOLD imaging to avoid gadolinium administration.…”
Section: Latest Technical Developments and Future Trendsmentioning
confidence: 99%