2015
DOI: 10.1016/s0140-6736(14)61903-6
|View full text |Cite
|
Sign up to set email alerts
|

Cardioverter defibrillator implantation without induction of ventricular fibrillation: a single-blind, non-inferiority, randomised controlled trial (SIMPLE)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

6
152
0
4

Year Published

2016
2016
2022
2022

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 222 publications
(162 citation statements)
references
References 31 publications
6
152
0
4
Order By: Relevance
“…Therefore, in many hospitals, dual-coil leads are favored in patients with HCM. 24 Our study showed the efficacy of a 25-J shock with the SVC coil "off", representing at least a 10-J safety margin for defibrillation.…”
Section: Disclosuresmentioning
confidence: 64%
See 1 more Smart Citation
“…Therefore, in many hospitals, dual-coil leads are favored in patients with HCM. 24 Our study showed the efficacy of a 25-J shock with the SVC coil "off", representing at least a 10-J safety margin for defibrillation.…”
Section: Disclosuresmentioning
confidence: 64%
“…22, 23 Randomized trials have now shown that left-sided ICD implantation without DFT testing is non-inferior to implantation with DFT testing. 22, 24 In addition, shock therapy may adversely affect prognosis, whether appropriate or inappropriate, although controversy persists as to whether that reflects a greater degree of underlying illness or a primary shock effect. Relationship between shock impedance and shock pulse width.…”
Section: Discussionmentioning
confidence: 99%
“…10,12) The SIMPLE trial is a single blind, randomized, multicenter trial, evaluating the non-inferiority of non-testing versus testing using a composite outcome of arrhythmic death or failed appropriate shocks for ventricular arrhythmias. From its study, the authors concluded that routine DFT testing at the time of the ICD implantation is generally well tolerated but does not improve the shock efficacy or reduce the arrhythmic death.…”
Section: Discussionmentioning
confidence: 99%
“…However, previous reports showed that the DFT testing during ICD implantations is neither effective nor beneficial. [3][4][5][6][7][8][9] The SIMPLE trial 10) is a single-blind, randomized, multicenter, non-inferiority trial comparing the efficacy and safety of ICD implantations with DFT or without DFT testing. Recently it demonstrated that a routine DFT test at the time of the ICD implantation does not improve shock efficacy or reduce arrhythmic death.…”
mentioning
confidence: 99%
“…In recent years, the advent of the biphasic waveform, better understanding of optimal shock waveform/duration, and higher-shock energy devices, have led some to question the need for defibrillation testing (DFT) [1]. Furthermore, controversy over whether to perform DFT has focused on possible adverse clinical events [1][2][3][4]. A prior systematic review by Phan et al [5] demonstrates no significant benefit for DFT in terms of mortality, ICD efficacy or 30-day post-implant complications.…”
Section: Introductionmentioning
confidence: 99%