specimen breaks. The difference in the readings of the previously graduated micrometer also determines the load which breaks the specimen.The fragment of filamentary crystal attached to the lower quartz filament is studied under a microscope and its diameter is measured in different planes. The area of the cross section is calculated as the area of a circle with the average diameter of these measurements.The diameter is measured to an accuracy of • 0.5 #m which is 17, 10, and 7%, respectively, for diameters of 3, 5, and 7 ~m.Consequently, the area of the cross section is determined to an accuracy of 34, 20, and 14%, respectively.The measurement of the areas of the cross section of the filamentary crystals involves a fundamental error in the determination of their strength since the load is measured to an accuracy of + 10 mg which is 0.2-0.3%. The achievable accuracy of the determination of the strength of an MgO FC can be regarded as completely satisfactory since the majority of crystals are 5-7/~m and the large number of the measurements makes it possible when treating the results to use statistical methods with adequate reliability.The ultimate extensive strength of the crystals varied from 500 to 1500 MPa depending on their diameter.