2015
DOI: 10.1016/j.ijcard.2015.04.146
|View full text |Cite
|
Sign up to set email alerts
|

Catheter ablation of idiopathic ventricular tachycardia without the use of fluoroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
26
0
2

Year Published

2019
2019
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 35 publications
(31 citation statements)
references
References 22 publications
0
26
0
2
Order By: Relevance
“…Some studies have demonstrated the ability of electroanatomic mapping (EAM) systems to minimize or eliminate the unnecessary doses of radiation . However, there are only a few cases published with a full 3D‐mapping system approach and complete elimination of the use of RX . In 2011, we started an RX‐minimization programme in all of our procedures using the CARTO system, with the deliberate intention to not resort to the aid of RX unless strictly necessary.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Some studies have demonstrated the ability of electroanatomic mapping (EAM) systems to minimize or eliminate the unnecessary doses of radiation . However, there are only a few cases published with a full 3D‐mapping system approach and complete elimination of the use of RX . In 2011, we started an RX‐minimization programme in all of our procedures using the CARTO system, with the deliberate intention to not resort to the aid of RX unless strictly necessary.…”
Section: Introductionmentioning
confidence: 99%
“…4 However, there are only a few cases published with a full 3D-mapping system approach and complete elimination of the use of RX. 5,6 In 2011, we started an RXminimization programme in all of our procedures using the CARTO system, with the deliberate intention to not resort to the aid of RX unless strictly necessary. All patients with atrial tachycardia (AT), AFL, and idiopathic VT were considered to be candidates for this "zero-RX" strategy.…”
Section: Introductionmentioning
confidence: 99%
“…The use of 3D mapping systems not only allow correct understanding of the anatomical relationship when one is approaching the ablation target from different sites but also significantly reduce fluoroscopy time. In fact, many of these procedures can be performed completely without the use of fluoroscopy . In a fluoroscopic view it may be difficult to determine where the pulmonary valve is located exactly.…”
Section: Chapter 10: Idiopathic Outflow Tract Ventricular Tachycardiamentioning
confidence: 99%
“…In fact, many of these procedures can be performed completely without the use of fluoroscopy. 251 In a fluoroscopic view it may be difficult to determine where the pulmonary valve is located exactly. Using 3D mapping systems it could be shown that a voltage cutoff value of 1.9 mV accurately delineates the level of the pulmonary valve.…”
Section: Rvot-vtmentioning
confidence: 99%
See 1 more Smart Citation