2014
DOI: 10.1016/j.avsg.2014.03.016
|View full text |Cite
|
Sign up to set email alerts
|

Catheter-directed Thrombolysis for Severe Pulmonary Embolism in Pediatric Patients

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
24
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 27 publications
(25 citation statements)
references
References 31 publications
1
24
0
Order By: Relevance
“…The EKOS system has been shown to be as effective as therapy with lytic agents alone, while reducing infusion times and the incidence of therapy‐related complications . The EKOS system has been used in children ; however, to our knowledge, the infant in our series is the smallest child to date in whom the EKOS system has been used. While this system holds promise for the treatment of thrombotic disease in children, the catheter system currently requires a 6 Fr introducer sheath and must be left indwelling for generally at least 24 hr.…”
Section: Discussionmentioning
confidence: 94%
“…The EKOS system has been shown to be as effective as therapy with lytic agents alone, while reducing infusion times and the incidence of therapy‐related complications . The EKOS system has been used in children ; however, to our knowledge, the infant in our series is the smallest child to date in whom the EKOS system has been used. While this system holds promise for the treatment of thrombotic disease in children, the catheter system currently requires a 6 Fr introducer sheath and must be left indwelling for generally at least 24 hr.…”
Section: Discussionmentioning
confidence: 94%
“…Upon our review of the literature, we identified 15 patients with submassive PE from four retrospective cohort studies who had undergone CDT (including the NCH cohort; Supporting Information Table S2). CDT was well tolerated with only one patient developing a mild gastrointestinal bleed that was medically managed. Additionally, all 15 patients had normalization of right ventricular function on post‐intervention echocardiography.…”
Section: Discussionmentioning
confidence: 99%
“…Upon our review of the literature, we identified 15 patients with submassive PE from four retrospective cohort studies who had undergone CDT (including the NCH cohort; Supporting Information Table S2). 24…”
Section: Discussionmentioning
confidence: 99%
“…28 In patients with submassive pulmonary embolism, EkoSonic Endovascular System catheter-directed thrombolysis is an approved treatment methodology for adult patients, but it is not performed widely in pediatric patients, so experience in this setting is limited. 29 The 2 classic trials that specify a dosing protocol and duration of treatment for ultrasound-assisted thrombolysis are the ULTIMA and the SEATTLE II trials. 16,17 These studies were based on adult populations and used the EkoSonic Endovascular System.…”
Section: Discussionmentioning
confidence: 99%