2023
DOI: 10.1002/14651858.cd012478.pub2
|View full text |Cite
|
Sign up to set email alerts
|

Catheter insertion techniques for improving catheter function and clinical outcomes in peritoneal dialysis patients

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 68 publications
0
5
0
Order By: Relevance
“…Recently, a review of PD catheter placement techniques for improving catheter function and clinical outcomes was published. 19 The review showed that laparoscopic surgery may reduce the risk of catheter tip migration. On the other hand, the present study showed that the surgical method and adjunctive techniques did not affect catheter patency, and high catheter patency was obtained.…”
Section: Discussionmentioning
confidence: 99%
“…Recently, a review of PD catheter placement techniques for improving catheter function and clinical outcomes was published. 19 The review showed that laparoscopic surgery may reduce the risk of catheter tip migration. On the other hand, the present study showed that the surgical method and adjunctive techniques did not affect catheter patency, and high catheter patency was obtained.…”
Section: Discussionmentioning
confidence: 99%
“…In contrast to the study's conclusions, a recent systematic review by Briggs et al reported low-quality evidence, finding no significant differences in PD catheter dysfunction rates among various insertion techniques in randomized controlled studies. 2 The second concern is the considerable variation in early pericatheter leakage observed in studies of urgent start PD. 3 Factors such as catheter break-in time, insertion technique, initial dwell volumes, treatment modality, and catheter securing strategies are significant sources of variation.…”
mentioning
confidence: 99%
“…In contrast to the study's conclusions, a recent systematic review by Briggs et al reported low-quality evidence, finding no significant differences in PD catheter dysfunction rates among various insertion techniques in randomized controlled studies. 2…”
mentioning
confidence: 99%
“…In addition, we would emphasize that our study does not examine the association between insertion techniques and complication rates after PD catheter placement, which is the focus of the systematic review by Briggs et al highlighted by Dr. Sahutoglu. 3 Instead, our study accounts for the insertion technique in all models when examining differences in complication rates by specialty. Although we agree that having better insertion techniques to prevent leakage, even with early use of PD catheters, would be helpful overall, our primary analysis excluded catheters that were used urgently or in an acute fashion (although these procedures were included in sensitivity analyses).…”
mentioning
confidence: 99%