2017
DOI: 10.21809/rilemtechlett.2017.38
|View full text |Cite
|
Sign up to set email alerts
|

Cathodic protection in reinforced concrete structures affected by macrocell corrosion: a discussion about the significance of the protection criteria

Abstract: Cathodic protection is a technique that has been used to control corrosion and increase the service life of reinforced concrete structure. Standards as EN ISO 12696 give protection criteria for both impressed current and sacrificial anodes techniques, based on potential value or decay during a depolarization sequence. The polarization (current ON) and depolarization (current OFF) are experimentally studied on a corroded concrete wall using six references electrodes and compared to a time-dependent modelling us… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
2
0
1

Year Published

2018
2018
2023
2023

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 13 publications
0
2
0
1
Order By: Relevance
“…The skyscraper has a raft foundation that is 3.7 m thick, and cooperates with 192 piles that are 47 m in length [39]. A cathodic protection system creates a barrier to protect structure from polluted ground water affecting the concrete [40]. The main structural system for this mega-structure is the buttressed core, which allows a very big increase in height.…”
Section: Burj Khalifa (Dubai Uae)-the Highest Mega-structure Systemmentioning
confidence: 99%
“…The skyscraper has a raft foundation that is 3.7 m thick, and cooperates with 192 piles that are 47 m in length [39]. A cathodic protection system creates a barrier to protect structure from polluted ground water affecting the concrete [40]. The main structural system for this mega-structure is the buttressed core, which allows a very big increase in height.…”
Section: Burj Khalifa (Dubai Uae)-the Highest Mega-structure Systemmentioning
confidence: 99%
“…L'étude expérimentale réalisée sur le mur M3PC et présentée dans cet article a montré que la protection cathodique pouvait être réalisée alors que le potentiel « instant OFF » de l'acier était voisin de À250 à À300 mV/ Ag/AgCl 0,5 M. Par ailleurs, le champ de potentiel avant, pendant et après polarisation cathodique est non uniforme. Une étude complémentaire réalisée par Laurens et François [32] mesurant simultanément les potentiels E OFF en six points différents du mur M3PC a confirmé la nonuniformité des potentiels E OFF .…”
Section: Conclusion-perspectivesunclassified
“…Application of cathodic protection system (CP) on reinforced concrete structure has been developed to prevent the onset of corrosion either for existing reinforced concrete structures or to new RC structures [5].…”
Section: Introductionmentioning