2013
DOI: 10.1016/j.radphyschem.2013.02.023
|View full text |Cite
|
Sign up to set email alerts
|

CBED electron beam drilling and closing of holes in decahedral silver nanoparticles

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
8
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(9 citation statements)
references
References 33 publications
1
8
0
Order By: Relevance
“…In the case of silver particles, Tehuacanero-Cuapa et al (1) suggested that the viability of the material observed around the hole. The driving force would be based on relaxation of mechanical distortions created by the defects induced by the electron beam during drilling the hole.…”
Section: Recovery and Recrystallizationmentioning
confidence: 99%
See 1 more Smart Citation
“…In the case of silver particles, Tehuacanero-Cuapa et al (1) suggested that the viability of the material observed around the hole. The driving force would be based on relaxation of mechanical distortions created by the defects induced by the electron beam during drilling the hole.…”
Section: Recovery and Recrystallizationmentioning
confidence: 99%
“…However, recently Tehuacanero-Cuapa et al (1) have shown that holes are produced at the site of incidence when silver decahedral particles are irradiated with the electron beam in the CBED condition. Returning to observe the hole in the high-resolution image HRTEM mode, it is closed.…”
Section: Introductionmentioning
confidence: 99%
“…Normal CBED patterns of volumetric materials show dynamic contrast within the bright discs, as well as diffuse Kikuchi bands and sharp HOLZ lines, but the CBED patterns of nanoparticles only show bright kinematical discs [8]. In addition to this, Tehuacanero-Cuapa et al [14], trying to obtain CBED patterns in Au decahedral nanoparticles of less than 30 nm in size, found that the electron beam perforated the Au nanoparticles, thus concluding that the CBED analysis should be performed with particles larger than 30-nm-in-size to avoid the perforation [14,15].…”
Section: Introductionmentioning
confidence: 92%
“…It is worth mentioning that hollows in MTPs can also be produced by different strategies using chemical etching [135] and surfactants [136], galvanic [137][138][139] and Kirkendall [140][141][142] replacement of components, and electron beam irradiation [143][144][145].…”
Section: The Intrinsic Structure Of Multiply Twinned Particlesmentioning
confidence: 99%