2011
DOI: 10.1016/j.talanta.2011.07.088
|View full text |Cite
|
Sign up to set email alerts
|

Cellulose microfiber functionalized with N,N′-bis (2-aminoethyl)-1,2-ethanediamine as a solid sorbent for the fast preconcentration of Cd(II) in flow system analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0
2

Year Published

2012
2012
2020
2020

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 38 publications
(11 citation statements)
references
References 39 publications
0
9
0
2
Order By: Relevance
“…The minicolumn was connected at the sampling loop place of the injector, and all the connections were kept as short as possible to minimize dead volumes. The on-line continuous flow copper enrichment system used in the present research was previously reported by our research group [21]. In the preconcentration step, 13 mL of the sample solution (pH 9.13, 0.14 mol L −1 ammoniacal buffer) were percolated through the minicolumn at a flow rate of 5.0 mL min −1 .…”
Section: Minicolumn Preparation and On-line Continuous Flow Copper Enmentioning
confidence: 99%
“…The minicolumn was connected at the sampling loop place of the injector, and all the connections were kept as short as possible to minimize dead volumes. The on-line continuous flow copper enrichment system used in the present research was previously reported by our research group [21]. In the preconcentration step, 13 mL of the sample solution (pH 9.13, 0.14 mol L −1 ammoniacal buffer) were percolated through the minicolumn at a flow rate of 5.0 mL min −1 .…”
Section: Minicolumn Preparation and On-line Continuous Flow Copper Enmentioning
confidence: 99%
“…Na sequência, as amostras foram resfriadas com adição posterior de 5 mL de H 2 O 2 30% (v/v). 24 A solução resultante foi aquecida em chapa de aquecimento em cerca de 100 o C até quase a secura, com ajuste posterior do pH em 2,0 e aferição em balão volumétrico de 50 mL. No preparo da amostra de chá solúvel, 390 mg foram dissolvidos em 40 mL de água fervente.…”
Section: Amostras/preparo Das Amostrasunclassified
“…chelating agent for metals) to a wide range of natural and pre synthesised solid supports. Among the favered preferred subtances are; silica gel [18][19][20], activated carbon [21,22], chelating ion exchange resins [23], naphthalene [24], zeolite [25], C18 [26], cellulosic derivatives [27], alumina [28,29], and XAD resins [30]. Extensive overview with demonstrative examples of the diffrent preparation methods for chelating resins can be found in many comperhensive reviews [30][31][32].…”
Section: Introductionmentioning
confidence: 99%