2017
DOI: 10.1126/scitranslmed.aag1303
|View full text |Cite
|
Sign up to set email alerts
|

Central-acting therapeutics alleviate respiratory weakness caused by heart failure–induced ventilatory overdrive

Abstract: Diaphragmatic weakness is a feature of heart failure (HF) associated with dyspnea and exertional fatigue. Most studies have focused on advanced stages of HF, leaving the cause unresolved. The long-standing theory is that pulmonary edema imposes a mechanical stress, resulting in diaphragmatic remodeling, but stable HF patients rarely exhibit pulmonary edema. We investigated how diaphragmatic weakness develops in two mouse models of pressure overload-induced HF. As in HF patients, both models had increased eupne… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
37
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 19 publications
(37 citation statements)
references
References 98 publications
0
37
0
Order By: Relevance
“…Oesophageal pressure measurements were performed as previously described . Briefly, mice were anesthetized with an isoflurane/oxygen mix (2%:100%), and body temperature was maintained at 37°C.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Oesophageal pressure measurements were performed as previously described . Briefly, mice were anesthetized with an isoflurane/oxygen mix (2%:100%), and body temperature was maintained at 37°C.…”
Section: Methodsmentioning
confidence: 99%
“…27 Oesophageal pressure transduction Oesophageal pressure measurements were performed as previously described. 28 Briefly, mice were anesthetized with an isoflurane/oxygen mix (2%:100%), and body temperature was maintained at 37°C. Mice were intubated using a 20gauge angiocatheter (Becton, Dickinson and Company) to maintain an open/unobstructed airway.…”
Section: In Vivo Micro-computed Tomography Scansmentioning
confidence: 99%
“…Samples were homogenized in buffer with a phosphatase and protease inhibitor cocktail and total protein content was measured by the bicinchoninic acid assay as described previously (Foster et al 2017). Briefly, samples were loaded onto a 4-20% Criterion TGX precast gel (Bio-Rad) alongside 10 μL of Precision Plus Protein Standards Kaleidoscope ladder (Bio-Rad) and then separated by SDS-PAGE followed by immunoblotting.…”
Section: Immunoblottingmentioning
confidence: 99%
“…Alternatively, animal models are used to investigate the chronology of cardiac events to a particular stress over time. Temporal studies in animal models provide insight into the time course of remodeling patterns ( Mirsky et al, 1983 ; Inoko et al, 1994 ; Klotz et al, 2006 ), and are valuable in the search for disease mechanisms and treatment targets ( Foster et al, 2017 ).…”
Section: Introductionmentioning
confidence: 99%