2017
DOI: 10.1109/tpwrd.2016.2600278
|View full text |Cite
|
Sign up to set email alerts
|

Centralized Protection Strategy for Medium Voltage DC Microgrids

Abstract: Abstract-1 This paper presents a centralized protection strategy for medium voltage dc (MVDC) microgrids. The proposed strategy consists of a communication-assisted fault detection method with a centralized protection coordinator and a fault isolation technique that provides an economic, fast, and selective protection by using the minimum number of dc circuit breakers (DCCBs). The proposed method is also supported by a backup protection which is activated if communication fails. The paper also introduces a cen… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
84
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 163 publications
(84 citation statements)
references
References 25 publications
0
84
0
Order By: Relevance
“…The LL faults create very serious harm to the safety of the system, and it has low fault impedance characteristics. On the other hand, the LG faults are the most frequently occurring faults that cause damage by the grounding system type in the DC network . During the selection of the suitable grounding system type, many related factors are taken into account like lessening the stray current, minimization of touch current for enhancing the personal safety, and fault current amplitude .…”
Section: Challenges Towards the Protection Of Microgridmentioning
confidence: 99%
See 1 more Smart Citation
“…The LL faults create very serious harm to the safety of the system, and it has low fault impedance characteristics. On the other hand, the LG faults are the most frequently occurring faults that cause damage by the grounding system type in the DC network . During the selection of the suitable grounding system type, many related factors are taken into account like lessening the stray current, minimization of touch current for enhancing the personal safety, and fault current amplitude .…”
Section: Challenges Towards the Protection Of Microgridmentioning
confidence: 99%
“…On the other hand, the LG faults are the most frequently occurring faults that cause damage by the grounding system type in the DC network. 27,28 During the selection of the suitable grounding system type, many related factors are taken into account like lessening the stray current, minimization of touch current for enhancing the personal safety, and fault current amplitude. 29 The corrosion is the main consequence of stray current, and this forces to design a protection scheme with minimum stray current.…”
Section: Groundingmentioning
confidence: 99%
“…13 can be converted to the V ce_n and V ce_n of SSCB using (7). The V ce_n and V ce_p are derived as given in (11). (11) It should be noticed that the current at the first valid point used for calculation should be larger than I min .…”
Section: ) Voltage Threshold Setting For Mode Selection Unitmentioning
confidence: 99%
“…For example, the authors of [2,3] used IEC 61850 to (respectively) adapt the 67/67N protection of main ring systems featuring distributed energy resources and to improve the fault detection times of protection relays in different substations. IEC 61850 has also been usefully applied to microgrids and distribution networks [4][5][6][7]. The authors of [4,5] proposed centralized protection strategies for microgrids and the authors of [6] proposed the design of microgrid plug-and-play functions in accordance with IEC 61850.…”
Section: Introductionmentioning
confidence: 99%
“…IEC 61850 has also been usefully applied to microgrids and distribution networks [4][5][6][7]. The authors of [4,5] proposed centralized protection strategies for microgrids and the authors of [6] proposed the design of microgrid plug-and-play functions in accordance with IEC 61850. In [7], the three-level coordinated control was proposed for voltage regulation in distribution networks and its effectiveness was validated by experiment through a real communication link.…”
Section: Introductionmentioning