2018
DOI: 10.2172/1466215
|View full text |Cite
|
Sign up to set email alerts
|

Cesium Ion Exchange Testing Using Crystalline Silicotitanate with Hanford Tank Waste 241-AP-107

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
18
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
5
3

Relationship

4
4

Authors

Journals

citations
Cited by 9 publications
(18 citation statements)
references
References 0 publications
0
18
0
Order By: Relevance
“…Measurements were conducted by PNNL's ASO organization in RPL according to the Analytical Service Requests (ASR) 0543 (gamma) and 0552 (total activity). The activity for each sample was measured and compared to the parent AP-107 feed analysis completed and reported by Rovira et al (2018) as part of PNNL's Radioactive Test Platform 1 work.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Measurements were conducted by PNNL's ASO organization in RPL according to the Analytical Service Requests (ASR) 0543 (gamma) and 0552 (total activity). The activity for each sample was measured and compared to the parent AP-107 feed analysis completed and reported by Rovira et al (2018) as part of PNNL's Radioactive Test Platform 1 work.…”
Section: Resultsmentioning
confidence: 99%
“…6.2 (a) 241-AP-107 sample 7AP-17-11 GEA results reported by Rovira et al (2018) The actual samples of interest for the purpose of Hg species quantification using CVAFS are the Carbotrap ® and gold-coated sand substrate materials. These traps will eventually be heated and purged with an inert gas to desorb, volatilize, and deliver the mercury to the fluorescence detector.…”
Section: Resultsmentioning
confidence: 99%
“…The AP-107 waste was delivered in two portions, one of approximately 4.8 L and a second of approximately 3.8 L. The composition of the AP-107 waste after solids and cesium removal was analyzed by Rovira et al (2018). The mass of each GFC to be added to the separate portions of the AP-107 waste was calculated by the glass models documented in Kim et al (2012) to satisfy the WTP baseline requirements and the GFCs masses are given in Table 2.2.…”
Section: Melter Feed Preparationmentioning
confidence: 99%
“…A second waste portion was received at the RPL, the supernatant from Hanford tank 241-AP-107 (hereafter called AP-107). This AP-107 waste went through solids removal by filtration (Geeting et al 2018b) and cesium removal by ion exchange (Rovira et al 2018); this test report describes the results 1.2 from the vitrification of the treated AP-107 waste in the CLSM in RPL. The vitrification test was performed in August 2018, during which glass product and off-gas effluents, both gaseous and liquid, were collected for elemental analysis.…”
Section: Introductionmentioning
confidence: 99%
“…The above two parameters were revised, based on recent Pacific Northwest National Laboratory (PNNL) data where a recently manufactured batch of UOP CST media (IONSIV TM R9140-B received in 2018) was used for testing. The new CST batch specific information employed was the batch contact tests and column breakthrough tests performed by Fiskum et al (2018) for a simple simulant and by Rovira et al (2018) for actual AP-107 tank waste. There are some results from this testing that are not consistent with historical observations (discussed later in this report), but, given the urgency in arriving at an acceptable column size best estimate, we employed these test results to establish more batch-specific parameter values: To accomplish the column sizing and sensitivity studies mentioned above, several computational tasks were performed and are discussed in subsequent sections of this report.…”
Section: Introductionmentioning
confidence: 99%