2023
DOI: 10.1016/j.solener.2023.05.019
|View full text |Cite
|
Sign up to set email alerts
|

CFD modelling of an indirect thermocline energy storage prototype for CSP applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 26 publications
0
3
0
Order By: Relevance
“…And to obtain the highest thermal energy, the values of the temperature between 150 o C to 240 o C were used from 8 am to 17 pm, and the working hours vary according to the year seasons [57][58][59][60][61][62][63][64][65][66][67]. According to the results of some researchers [18,34,58,[68][69][70][71][72], at an air temperature of 35, the system gives a heat concentration of up to 403 degrees Celsius, produced by one equivalent dish, equivalent to 4576 watts. And according to the estimate of the energy required for this work, it requires the installation of 8 solar collectors.…”
Section: Components and Alternative Of Orc Working Fluidsmentioning
confidence: 99%
“…And to obtain the highest thermal energy, the values of the temperature between 150 o C to 240 o C were used from 8 am to 17 pm, and the working hours vary according to the year seasons [57][58][59][60][61][62][63][64][65][66][67]. According to the results of some researchers [18,34,58,[68][69][70][71][72], at an air temperature of 35, the system gives a heat concentration of up to 403 degrees Celsius, produced by one equivalent dish, equivalent to 4576 watts. And according to the estimate of the energy required for this work, it requires the installation of 8 solar collectors.…”
Section: Components and Alternative Of Orc Working Fluidsmentioning
confidence: 99%
“…Cagnoli et al established and validated a transient 2D CFD model for an indirect SMTHS tank, equipped with two flat tube heat exchangers [47]. The simulation results for the tank's charging and discharging processes indicated that the bypass in the heat exchanger position significantly reduced the thermal performance of the THS system.…”
Section: Heat Exchanger Configurationmentioning
confidence: 99%
“…Various types of models have been developed to investigate different aspects of THS. In the recent literature, software tools employed for numerical studies on THS include Ansys CFX [8], Ansys Fluent [27,46,47], Aspen Hysys [144], COMSOL [79], COMSOL Multiphysics [49,70,127], TRNSYS [42,147], NEST [19], EBSILON [72], and Star-CCM+ [47].…”
Section: Optimization Of Thermocline Heat Storage System Numerical Modelmentioning
confidence: 99%