2022
DOI: 10.1016/j.apsusc.2022.154525
|View full text |Cite
|
Sign up to set email alerts
|

Challenges in the interpretation of gas core levels for the determination of gas-solid interactions within dielectric porous films by ambient pressure XPS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 8 publications
(3 citation statements)
references
References 49 publications
0
3
0
Order By: Relevance
“…Details about the characteristics of the setup can be found in ref. ( 27 ). The μ-FOCUS source used monochromated AlK α radiation at 1486.7 eV, and it was operated at 50 W, with a spot size of approximately 285 μm in diameter and a photon irradiance of 35 μW/mm 2 .…”
Section: Methodsmentioning
confidence: 99%
“…Details about the characteristics of the setup can be found in ref. ( 27 ). The μ-FOCUS source used monochromated AlK α radiation at 1486.7 eV, and it was operated at 50 W, with a spot size of approximately 285 μm in diameter and a photon irradiance of 35 μW/mm 2 .…”
Section: Methodsmentioning
confidence: 99%
“…As could be seen, the binding energy of elements was observed at 572.0, 530.8, 366.9, 399.1, 335.0, 284.0, 82.9 and 67.2 eV, respectively. According to the literature, [43][44][45][46] they were identified as the characteristic peaks of Au 4P 3/2 , O 1s, Ag 3d, N 1s, Au 4d, C 1s, Au 4f and Br 3d, respectively. The exposure of reactive Br 3d to the surface demonstrated that UATRP was successfully implemented.…”
Section: Characterization Of the Lps Electrochemical Sensormentioning
confidence: 99%
“…Therefore, the main issues encountered are two: (i) the electrostatic charging of the samples during the XPS leads to a deformation of the gas peaks; (ii) the gas molecules are spatially distributed in different environments subjected to different local electrostatic potentials (the porous bulk of the sample, the sample surface, and the free gas volume over the sample surface) so that it is difficult to determine what fraction of the detected molecules might be in actual physical contact with the pore walls. The research done until now identifies the issues that need to be taken into account [143] and has started developing strategies to address these issues. [144] We believe that the technique will be further developed and that it has the potential to supply information about both chemical and physical interactions between gas and porous materials such as membranes.…”
Section: Outlook Perspectivesmentioning
confidence: 99%