2016
DOI: 10.2106/jbjs.n.01280
|View full text |Cite
|
Sign up to set email alerts
|

Changes in Muscle Oxygen Saturation Have Low Sensitivity in Diagnosing Chronic Anterior Compartment Syndrome of the Leg

Abstract: Changes in muscle oxygen saturation during and after an exercise test that elicits leg pain cannot be used to distinguish between patients with CACS and patients with other causes of exercise-induced leg pain.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

2
15
1
3

Year Published

2018
2018
2024
2024

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 10 publications
(21 citation statements)
references
References 16 publications
2
15
1
3
Order By: Relevance
“…IMP was measured continuously with a catheter in the test leg of the subject using a micro-capillary infusion system (Hemo 4; Siemens, Erlangen, Germany) and monitor (Siemens SC 9000; Siemens, Gothenburg, Sweden), which have been used previously in studies on the same muscle compartment [17, 18]. The IMP measurements were randomized to the left or right leg before the test, and the same leg was monitored at both sessions for each subject.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…IMP was measured continuously with a catheter in the test leg of the subject using a micro-capillary infusion system (Hemo 4; Siemens, Erlangen, Germany) and monitor (Siemens SC 9000; Siemens, Gothenburg, Sweden), which have been used previously in studies on the same muscle compartment [17, 18]. The IMP measurements were randomized to the left or right leg before the test, and the same leg was monitored at both sessions for each subject.…”
Section: Methodsmentioning
confidence: 99%
“…Oxygenation of muscle tissue is directly related to the balance between oxygen consumption and oxygen supply. Near-infrared spectroscopy (NIRS) provides continuous information about the absolute level of muscle oxygenation in an exercising muscle [17, 19]. The NIRS probe unit consists of two detector photodiodes and three laser-emitting diodes held 4 cm apart.…”
Section: Methodsmentioning
confidence: 99%
“…Van den Brand et al [6] evaluierten ebenfalls die NIRS als nichtinvasive Alternative zur intrakompartimentellen Druckmessung.…”
Section: Nahinfrarotspektroskopieunclassified
“…Eine aktuellere Arbeit von Rennerfelt [6] steht in Kontroverse zu den Arbeiten von van den Brand und Mohler, sodass der Stellenwert der Nahinfrarotspektroskopie in der Diagnostik des funktionellen Komartmentsyndroms weiterhin offen bleibt und weiterhin kritisch beobachtet oder weitergehend untersucht werden sollte. Bei unserem Patientengut hat sich eine seitenvergleichende Messung unter symmetrischer Belastung als hilfreich erwiesen.…”
Section: Nahinfrarotspektroskopieunclassified
See 1 more Smart Citation