2008
DOI: 10.1213/ane.0b013e31816841c0
|View full text |Cite
|
Sign up to set email alerts
|

Changing Patterns in Anesthetic Fresh Gas Flow Rates Over 5 Years in a Teaching Hospital

Abstract: Fresh gas flows used in our department have decreased by 35% over 4 years. Although the absolute change in flow rate is not large, this represents potential annual savings of more than $US130,000. This occurred without specific initiatives, suggesting an evolution in practice towards lower fresh gas flow. Improvements in equipment and monitoring, including a locally developed system, which displays forward predictions of end-tidal and effect-site vapor concentrations, may be factors in this change.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

3
23
0
2

Year Published

2010
2010
2018
2018

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 36 publications
(28 citation statements)
references
References 8 publications
3
23
0
2
Order By: Relevance
“…Biz bu yanlışlığın arkasında uygulayıcıların bilgi eksiklikleri, uygulamaya tanıdık olmayışları ve eski alışkanlıkların sürdürülmesi gereksiniminin olduğuna inanıyoruz. Düşük akım eğitiminin uygulayıcıların bu konudaki eğilimlerini değiştirdiğine ve konu ile ilgili protokoller oluşturul-masının tüketimi azalttığına dair kanıtlar mevcuttur (3,11,13) . Biz de bu çalışmamızda, eğitimin nihai anestezik gaz tüketiminde anlamlı düşüşlere yol açtığını gösterdik.…”
Section: Discussionunclassified
“…Biz bu yanlışlığın arkasında uygulayıcıların bilgi eksiklikleri, uygulamaya tanıdık olmayışları ve eski alışkanlıkların sürdürülmesi gereksiniminin olduğuna inanıyoruz. Düşük akım eğitiminin uygulayıcıların bu konudaki eğilimlerini değiştirdiğine ve konu ile ilgili protokoller oluşturul-masının tüketimi azalttığına dair kanıtlar mevcuttur (3,11,13) . Biz de bu çalışmamızda, eğitimin nihai anestezik gaz tüketiminde anlamlı düşüşlere yol açtığını gösterdik.…”
Section: Discussionunclassified
“…Using prices in 2010, Golembiewski [11 & ] calculated the usage costs per MAC hour of anesthesia at different fresh gas flow rates. Kennedy and French [14] reported institutional success in decreasing fresh gas flows by 35% over the span of 4 years, representing an annual savings of US$ 130 000. At our institution, current purchase prices per milliliter of isoflurane, sevoflurane, and desflurane are approximately half of that reported by Golembiewski in 2010.…”
Section: Cost Comparisons Of Different Inhalational Agentsmentioning
confidence: 99%
“…[2] Reducing anesthetic fresh gas flows can diminish inhaled anesthetic consumption without affecting drug delivery to the patient. [25] However, according to our clinical observation, the inspiratory and end-tidal concentrations detected by the analyzer are usually lower than the administrated vaporizer concentration if the fresh gas flow is lower than 4 L/minute. To keep the administration of isoflurane constant and its accurate detection in this study, consistent higher fresh gas flow (6 L/minute) was used to provide reliable body uptake and arterial blood concentrations during the entire procedure.…”
Section: Discussionmentioning
confidence: 99%