Channel depth, air mass flow rate and air distribution duct diameter optimization of photovoltaic thermal (PV/T) air collectors linked to residential buildings

Abstract: a b s t r a c tPhotovoltaic thermal (PV/T) air collector design requires an accurate determination of key parameters such as the channel depth and the air mass flow rate. This paper focuses on PV/T air collectors linked to an air distribution system with the aim of optimizing the channel depth, the air mass flow rate per unit collector area and the air distribution duct diameter considering the whole system performance. A weighted effective thermal energy output which includes electrical and thermal energy gen… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
37
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 117 publications
(37 citation statements)
references
References 25 publications
0
37
0
Order By: Relevance
“…6 Also, water cooling can be applied to cool the front side of PV panel. 11 To achieve high performance, some parameters have to be optimized including, but not limited to, collector depth, main duct diameter, and the mass flow rate of air. 7 In Schiro et al, 8 the authors examined different water spreading mechanism over PV panel until they achieved an acceptable uniform film.…”
Section: Introductionmentioning
confidence: 99%
“…6 Also, water cooling can be applied to cool the front side of PV panel. 11 To achieve high performance, some parameters have to be optimized including, but not limited to, collector depth, main duct diameter, and the mass flow rate of air. 7 In Schiro et al, 8 the authors examined different water spreading mechanism over PV panel until they achieved an acceptable uniform film.…”
Section: Introductionmentioning
confidence: 99%
“…It is feasible to make further use of the absorbed heat through a heat pump for one or more of the following purposes, i.e. hot water supply [23][24][25], space heating [26,27], solar cooling [28,29], thermal storage [30], desalination [31], drying [32,33] and pool heating [34,35] etc. Electricity generation from the PV cells, either exported to the national grid or stored in batteries, will meet the electrical load or drive the system component, i.e.…”
Section: Flat-plate Pv/t Modulesmentioning
confidence: 99%
“…Implementation to the fluids not only increases the efficiency but also mints uniform thermal output. In recent days, several notable works are done on photovoltaic cells, and the resultant parameters are measured and analyzed experimentally and numerically to find the efficient thermal system . The PV cells are integrated, and it is endorsed with the nanofluid to mint attractive figures compared with conventional system.…”
Section: Introductionmentioning
confidence: 99%
“…In recent days, several notable works are done on photovoltaic cells, and the resultant parameters are measured and analyzed experimentally and numerically to find the efficient thermal system. [7][8][9][10] The PV cells are integrated, and it is endorsed with the nanofluid to mint attractive figures compared with conventional system. Hasan et al incorporated PCM in building and found that the introduction of PCM in the building improves the solar radiation, temperature reduction, and regulated temperature in different seasons.…”
Section: Introductionmentioning
confidence: 99%