2017
DOI: 10.1299/jsmekansai.2017.92.m704
|View full text |Cite
|
Sign up to set email alerts
|

Characteristic Analysis of Thermal Triple-Axis Accelerometer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2017
2017
2020
2020

Publication Types

Select...
1
1

Relationship

2
0

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 0 publications
0
4
0
Order By: Relevance
“…Figure 3 a shows the 3D view of our model for the computational experiment, and Figure 3 b–d respectively show the side, top, and isometric views of the simplified schematic. The cavity structure was asymmetric in the up and down directions as in [ 7 , 8 , 9 , 10 ]. The heater loop consisted of four circular arcs subtending 45° and placed on a circle with a radius of 0.4 L , where L is the reference length.…”
Section: Steady-state Step Responsementioning
confidence: 99%
See 1 more Smart Citation
“…Figure 3 a shows the 3D view of our model for the computational experiment, and Figure 3 b–d respectively show the side, top, and isometric views of the simplified schematic. The cavity structure was asymmetric in the up and down directions as in [ 7 , 8 , 9 , 10 ]. The heater loop consisted of four circular arcs subtending 45° and placed on a circle with a radius of 0.4 L , where L is the reference length.…”
Section: Steady-state Step Responsementioning
confidence: 99%
“…Figure 2 b shows the third method. A cavity structure is created that is asymmetric in the up and down directions [ 7 , 8 , 9 , 10 ], and heat and temperature sensors are placed on the same plane. Because the shape of the deformed heat bubble varies according to the magnitude and sign of the acceleration in the z -direction, the measured temperature can determine the magnitude and sign of the acceleration.…”
Section: Introductionmentioning
confidence: 99%
“…Figure 2b shows the third method. A cavity structure is created that is asymmetric in the up and down directions [7][8][9][10], and heat and temperature sensors are placed on the same plane. Because the shape of the deformed heat bubble varies according to the magnitude and sign of the acceleration in the z-direction, the measured temperature can determine the magnitude and sign of the acceleration.…”
Section: Introductionmentioning
confidence: 99%
“…Figure 3a shows the 3D view of our model for the computational experiment, and Figure 3b-d respectively show the side, top, and isometric views of the simplified schematic. The cavity structure was asymmetric in the up and down directions as in [7][8][9][10]. The heater loop consisted of four circular arcs subtending 45 • and placed on a circle with a radius of 0.4 L, where L is the reference length.…”
Section: Introductionmentioning
confidence: 99%