Characteristics and limitations of a secondary dose check software for VMAT plan calculation

Abstract: Purpose: To assess the implementation, accuracy, and validity of the dosimetric leaf gap correction (DLGC) in Mobius3D VMAT plan calculations. Methods: The optimal Mobius3D DLGC was determined for both a TrueBeam with a Millennium multi-leaf collimator and a TrueBeamSTx with a high-definition multileaf collimator. By analyzing a broad series of seven VMAT plans and comparing the calculated to the measured dose delivered to a cylindrical phantom, optimal DLGC values were determined by minimizing the dose differ… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 11 publications
0
3
0
Order By: Relevance
“…However, in recent years, comparative studies for an overall range of clinically relevant plans, including intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT), have been performed. 20 22 , 29 , 30 Moreover, detailed characteristics of Mobius3D/FX, such as the dosimetric leaf gap (DLG) correction factor, have been explored for optimal performance. 20 22 , 30 , 31 In summary, in-depth evaluations of dosimetric accuracy of Mobius3D/FX for IMRT and VMAT plans have been actively performed.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…However, in recent years, comparative studies for an overall range of clinically relevant plans, including intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT), have been performed. 20 22 , 29 , 30 Moreover, detailed characteristics of Mobius3D/FX, such as the dosimetric leaf gap (DLG) correction factor, have been explored for optimal performance. 20 22 , 30 , 31 In summary, in-depth evaluations of dosimetric accuracy of Mobius3D/FX for IMRT and VMAT plans have been actively performed.…”
Section: Introductionmentioning
confidence: 99%
“… 20 22 , 29 , 30 Moreover, detailed characteristics of Mobius3D/FX, such as the dosimetric leaf gap (DLG) correction factor, have been explored for optimal performance. 20 22 , 30 , 31 In summary, in-depth evaluations of dosimetric accuracy of Mobius3D/FX for IMRT and VMAT plans have been actively performed. Yet, dosimetric accuracy for SBRT plans that mostly use flattening-filter-free (FFF) x-ray beams with small fields has not been intensively studied.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation