1981
DOI: 10.1107/s0021889881008856
|View full text |Cite
|
Sign up to set email alerts
|

Characteristics of a flat multiwire area detector for protein crystallography

Abstract: A flat, relatively thin (9 mm) xenon-filled multiwire proportional counter with two-dimensional, 2/~s delay line readout of a 270 x 300 mm active area has been developed for use as a position-sensitive area X-ray detector in the 8 keV energy region (Cu Ka) used in crystallographic structure work with large biological molecules. Its quantum detection efficiency for 8 keV Xray photons is about 0.5, a value which is spatially uniform to within _+ 2%. Its dead-time loss fraction at a typical data collection rate o… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
34
0

Year Published

1992
1992
2018
2018

Publication Types

Select...
6
4

Relationship

0
10

Authors

Journals

citations
Cited by 72 publications
(34 citation statements)
references
References 6 publications
0
34
0
Order By: Relevance
“…The cubic crystals are not seen to coexist with or transform into others. For data collection crystals were mounted by conventional means in quartz capillaries and intensities collected at 291 K using a two-panel multiwire areadetector system manufactured by San Diego Multiwire Systems equipped with a 20 table (Hamlin et al, 1981;Xuong, Nielson, Hamlin & Anderson, 1985). The X-ray source was a Rigaku RU-200 rotating anode operated at 45 kV and 145 mA and fitted with a Supper Co. graphite-crystal monochromator to yield Cu Ka radiation.…”
Section: Methodsmentioning
confidence: 99%
“…The cubic crystals are not seen to coexist with or transform into others. For data collection crystals were mounted by conventional means in quartz capillaries and intensities collected at 291 K using a two-panel multiwire areadetector system manufactured by San Diego Multiwire Systems equipped with a 20 table (Hamlin et al, 1981;Xuong, Nielson, Hamlin & Anderson, 1985). The X-ray source was a Rigaku RU-200 rotating anode operated at 45 kV and 145 mA and fitted with a Supper Co. graphite-crystal monochromator to yield Cu Ka radiation.…”
Section: Methodsmentioning
confidence: 99%
“…All of the mammalian cAPK crystal diffraction data were collected at 4°C with graphite monochromated CuKa X-rays from a Rigaku Ru-200 rotating anode diffractometer at the UCSD Research Resource equipped with two Xuong-Hamlin multiwire area detectors (Hamlin et al, 1981 ;Xuong et al, 1985). Statistics for the three data sets are summarized in Table 1.…”
Section: Data Collectionmentioning
confidence: 99%
“…Because of the detector setup, reflections were collected to 2.2 A, but usable data extended to about 2.75 A. The diffraction data were merged using the software provided by Area Detector Systems (Hamlin et al, 1981). A scale factor was calculated for multiple measurements and symmetry-related reflections.…”
Section: Data Collection and Processingmentioning
confidence: 99%