2007
DOI: 10.1016/j.expthermflusci.2007.06.008
|View full text |Cite
|
Sign up to set email alerts
|

Characteristics of wind power on Savonius rotor using a guide-box tunnel

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
50
0
1

Year Published

2008
2008
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 127 publications
(57 citation statements)
references
References 7 publications
0
50
0
1
Order By: Relevance
“…The blockage correction factor (f) is largely dependent on the type of wind tunnel test section used (open or closed type), and the blockage ratio (BR = area of turbine model to the area of test section). As found in open literature, the investigations related to blockage correction are mostly carried out in closed type test sections [36][37][38][39]. However, the correlations used for a closed type test section may not be appropriate for an open type test section under dynamic loading conditions.…”
Section: Experimental Validation and Blockage Correctionmentioning
confidence: 99%
“…The blockage correction factor (f) is largely dependent on the type of wind tunnel test section used (open or closed type), and the blockage ratio (BR = area of turbine model to the area of test section). As found in open literature, the investigations related to blockage correction are mostly carried out in closed type test sections [36][37][38][39]. However, the correlations used for a closed type test section may not be appropriate for an open type test section under dynamic loading conditions.…”
Section: Experimental Validation and Blockage Correctionmentioning
confidence: 99%
“…Figure 5 presents the variation of the torque coefficient C Md depending on the specific speed λ of the Savonius wind rotor for different external overlaps equal to (e''-e')/d=0, (e''-e')/d=0.1, (e''-e')/d=0.2 and (e''-e')/d=0. 3 According to these results, it has been noted that the gotten curves present a parabolic pace. Therefore, these results show that the external overlap value has an effect on the presentation of the power coefficient values.…”
Section: Introductionmentioning
confidence: 98%
“…The experimental results showed that the performance of Savonius wind rotors could be improved with a suitable curtain arrangement. Irabu and Roy [3] improved and adjusted the output power of Savonius rotor under various wind power and suggests the method of prevention the rotor from strong wind disaster. The experiments include the static torque test of the fixed rotor at any phase angle and the dynamic torque test at rotation of them.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…All rotors were assumed to have a diameter of 30 cm and a thickness of 2 mm considering the manufacturable size of a rotor. Rotor A has three blades with over gap, which is known as one of the models showing the highest performance for open space [18]. Rotor B has three particular-shaped blades and it is a merchandised model called GWE-200BI by Goldwind Energy in South Korea.…”
Section: Design Issue For Rotormentioning
confidence: 99%