2003
DOI: 10.1016/s0008-8846(02)00824-4
|View full text |Cite
|
Sign up to set email alerts
|

Characterization and monitoring of cement-based systems using intrinsic electrical property measurements

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
42
0
2

Year Published

2008
2008
2024
2024

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 108 publications
(45 citation statements)
references
References 16 publications
1
42
0
2
Order By: Relevance
“…The retarding effect of fly ash on hydration process appears in the resistivity parameters and compressive strength. The correlation electrical resistivity and compressive strength is plotted in Fig.6 as shown in Equation (4). It can be seen that the relationship exhibits a linear trend, and is independent on the fly ash incorporation.…”
Section: The Relationship Between Electrical Resistivity and Compressmentioning
confidence: 99%
See 2 more Smart Citations
“…The retarding effect of fly ash on hydration process appears in the resistivity parameters and compressive strength. The correlation electrical resistivity and compressive strength is plotted in Fig.6 as shown in Equation (4). It can be seen that the relationship exhibits a linear trend, and is independent on the fly ash incorporation.…”
Section: The Relationship Between Electrical Resistivity and Compressmentioning
confidence: 99%
“…(4) The compressive strength during 24 h to 48 h obtained from the resistivity measurement (using Equation 4) is compared with the experimental results of compressive strength as shown in Fig.7. It can be seen in Fig.7 that the measured results of compressive strength are reasonably close to the curves.…”
Section: The Relationship Between Electrical Resistivity and Compressmentioning
confidence: 99%
See 1 more Smart Citation
“…Conversely, simple, direct detection of intrinsic electrical properties, e.g., direct current (dc) resistivity, of CBM during hydration was proposed [12,13]. The four-probe (Wenner method) resistivity measurement used a simple setup, where no embedded sensors and alignment were required.…”
Section: Introductionmentioning
confidence: 99%
“…The development of the electrical resistivity with time can demonstrate the physical and chemical change from cement paste part. The electrical resistivity measurement has often been used to characterize hydration process of cement [3][4][5] , the effect on concrete inhibitors for steel in concrete [6] , the chloride diffusivity in concrete [7,8] , detection of damage during tensile loading of cement composites [9] , freezing of water in Portland cement paste [10] , water penetration in concrete [11] , setting time of concrete [12] , measuring the concrete internal moisture content [13] , and infl uence of aggregate fraction and mixture on the reliability of the rapid chloride permeability test [14,15] .…”
Section: Introductionmentioning
confidence: 99%