2019
DOI: 10.1016/j.ijhydene.2019.05.114
|View full text |Cite
|
Sign up to set email alerts
|

Characterization methodology for anode starvation in HT-PEM fuel cells

Abstract: Degradation caused by fuel starvation may be an important reason for limited fuel cell lifetimes. In this work, we present an analytical characterization of the high temperature polymer exchange membrane fuel cell (HT-PEM FC) behavior under cycled anode starvation and subsequent regeneration conditions to investigate the impact of degradation due to H 2 starvation. Two membrane electrode assemblies (MEAs) with an active area of 21 cm 2 were operated of up to 550 minutes, which included up to 14 starvation / re… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
8
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 12 publications
(9 citation statements)
references
References 36 publications
1
8
0
Order By: Relevance
“…Striking is the strong decrease of the CL layer on the anode and the adhesion of this layer to the membrane. These facts support the abovementioned assumption that the process of anode starvation was responsible for a main part of the degradation as observed by Yezerska et al [23]. Figure 5 shows the H 3 PO 4 contents of the tested MEA before (solid pillar) and after (striped pillar) the two long-term tests at a constant load of 0.3 A/cm 2 .…”
Section: During the Course Of The Test Of The Fmt-a Until 2000 H Of supporting
confidence: 88%
See 2 more Smart Citations
“…Striking is the strong decrease of the CL layer on the anode and the adhesion of this layer to the membrane. These facts support the abovementioned assumption that the process of anode starvation was responsible for a main part of the degradation as observed by Yezerska et al [23]. Figure 5 shows the H 3 PO 4 contents of the tested MEA before (solid pillar) and after (striped pillar) the two long-term tests at a constant load of 0.3 A/cm 2 .…”
Section: During the Course Of The Test Of The Fmt-a Until 2000 H Of supporting
confidence: 88%
“…The next recorded voltage reduction at approximately 1250 h was caused by a faulty supply of hydrogen. This fuel starvation also caused damage [23], causing the voltage to drop to 620 mV. From this incident, there was a slight regeneration [23] over the period up to approximately 1600 h to 625 mV but subsiding from here with a degradation rate of 23.3 µV/h to 604 mV after approximately 2450 h of operation.…”
Section: Resultsmentioning
confidence: 96%
See 1 more Smart Citation
“…Another responsible parameter for degrading PEM fuel cell performance and durability is starvation 117 . Starvation refers to an inadequate supply of fuel or oxidant under rapid load‐changing conditions 118 . Local starvation and overall starvation are two major types of reactant starvation 119 .…”
Section: Parameters Influencing the Performance Of Pem Fuel Cellmentioning
confidence: 99%
“…117 Starvation refers to an inadequate supply of fuel or oxidant under rapid load-changing conditions. 118 Local starvation and overall starvation are two major types of reactant starvation. 119 Both local starvation and overall starvation are the inadequate supply of reactant gas in a partial area of the CL and stack level, respectively.…”
Section: Catalyst Layermentioning
confidence: 99%