2020
DOI: 10.1016/j.radphyschem.2020.108746
|View full text |Cite
|
Sign up to set email alerts
|

Characterization of an extrapolation chamber in beta radiation beams and Monte Carlo modelling

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
2
0
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 15 publications
0
2
0
1
Order By: Relevance
“…The authors found differences to the calibration values of 4.8 %, 1.5 %, 4.2 %, 4.5 %, 7.7 % and 4.4 % for beta sources of 85 Kr (30 cm with filter) and 90 Sr/ 90 Y (11, 20, 30 and 50 cm without filter and 30 cm with filter), respectively. While Polo et al 2020 [16] presented results for 85 Kr, 90 Sr/ 90 Y (11 cm) and 147 Pm and likewise determined the absorbed dose rates to tissue at null depth. Differences with the calibration values found were 1 %, 0.2 % and 0.8 %, respectively.…”
Section: Absorbed Dose Rate To Tissue 𝑫 𝒕mentioning
confidence: 99%
See 1 more Smart Citation
“…The authors found differences to the calibration values of 4.8 %, 1.5 %, 4.2 %, 4.5 %, 7.7 % and 4.4 % for beta sources of 85 Kr (30 cm with filter) and 90 Sr/ 90 Y (11, 20, 30 and 50 cm without filter and 30 cm with filter), respectively. While Polo et al 2020 [16] presented results for 85 Kr, 90 Sr/ 90 Y (11 cm) and 147 Pm and likewise determined the absorbed dose rates to tissue at null depth. Differences with the calibration values found were 1 %, 0.2 % and 0.8 %, respectively.…”
Section: Absorbed Dose Rate To Tissue 𝑫 𝒕mentioning
confidence: 99%
“…Several computational MC codes are widely well known and used for radiation dosimetry such as, PENELOPE, GEANT4, FLUKA, EGSnrc, MCNP and others [8][9][10][11][12]. It is possible to find in literature publications reporting results on MC modelling and simulations using the varies MC codes available, of beta dosimetry systems with different types of extrapolation chambers [13][14][15][16][17][18][19][20][21][22]. However, there is no publication,…”
Section: Introductionmentioning
confidence: 99%
“…Vários códigos computacionais existem para a simulação do transporte de partículas e são utilizados como apoio às medidas experimentais (9,10). Diversos trabalhos publicados diariamente utilizam códigos de MC para diferentes cálculos nas áreas da dosimetria beta bem como em outras várias outras áreas de pesquisa (11)(12)(13).…”
Section: Introductionunclassified