The best achieved accuracies in both detection and classification were varied depending on the band, the correlation function, and the database. The most contributive bands in both detection and classification were between 1000 and 8000 Hz. In detection, the highest acquired accuracies when using cross-correlation were 99.809%, 90.979%, and 91.168% in the Massachusetts Eye and Ear Infirmary, Saarbruecken Voice Database, and Arabic Voice Pathology Database databases, respectively. However, in classification, the highest acquired accuracies when using cross-correlation were 99.255%, 98.941%, and 95.188% in the three databases, respectively.