1995
DOI: 10.1021/es00009a045
|View full text |Cite
|
Sign up to set email alerts
|

Characterization of Fulvic Acid by Laser-Desorption Mass Spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
35
0

Year Published

1997
1997
2015
2015

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 38 publications
(38 citation statements)
references
References 10 publications
3
35
0
Order By: Relevance
“…For HA and FA, only sporadic high peaks between 100 and 600 Da were observed, which is consistent with the literature [13,15,28]. These observations were also in accordance with the results obtained by the ultrafiltration method (Section 3.1).…”
Section: Global Shape Approachsupporting
confidence: 92%
See 1 more Smart Citation
“…For HA and FA, only sporadic high peaks between 100 and 600 Da were observed, which is consistent with the literature [13,15,28]. These observations were also in accordance with the results obtained by the ultrafiltration method (Section 3.1).…”
Section: Global Shape Approachsupporting
confidence: 92%
“…In MALDI, a protecting matrix is used to induce soft ionization due to the absorption of a large part of the laser energy by the matrix [13]. The mass spectra of Humic Substances are dominated by low molecular weight ions (usually between 500 and 3000 m/z ratio) [13][14][15][16]. According to the theory of supramolecular aggregates, individual components with low molecular weights (500-1500 Da) are bound by non-covalent bonds to form humic acid and fulvic acid [17].…”
Section: Introductionmentioning
confidence: 99%
“…SRFA was chosen as calibration compound for a quantitative HULIS determination because it is widely used and chemically well characterized (e.g., Noyes and Leenheer, 1989;Leland et al, 1999). In addition, the molecular size distribution of SRFA is <1000 Da as determined by various methods, among them LDI-MS and MALDI-MS (Novotny and Rice, 1995;Brown and Rice, 2000;Leenheer et al, 2001;Kujawinski et al, 2002). The same molecular size range is expected for HULIS (Kiss et al, 2003).…”
Section: Methodsmentioning
confidence: 88%
“…These features were proved for ESI of humic molecules in combination with high-resolution instrumentation such as Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (FT IRC-MS) providing a resolving power up to 120,000 for low-mass molecules [29,30,31,32]. A possible drawback in soft ionization of humic substances was indicated by Novotny and Rice [33] who, by using laser desorption ionization (LDI), suggested that formation of multiply charged ions may represent a bias in favor of low average molecular weight of humic molecules. Plancque and coworkers [25], using quadrupole time-of-flight (Q-TOF) ESI-MS, showed that singly charged ions were by far the most abundant ions generated from a fulvic acid.…”
Section: Introductionmentioning
confidence: 99%