2005
DOI: 10.1002/jms.940
|View full text |Cite
|
Sign up to set email alerts
|

Characterization of industrial alkylpolyphosphonates by infusion electrospray ionization‐ion trap mass spectrometry with identification of the impurities by tandem capillary zone electrophoresis

Abstract: Technical grade diethylene-triaminepentakis(methylenephosphonic acid) (I), dihexamethylene-triaminepentakis(methylenephosphonic acid) (II), ethylene-diaminetetrakis(methylenephosphonic acid) (III), hexamethylene-diaminetetrakis(methylenephosphonic acid) (IV), amino-tris(methylenephosphonic acid) (V), hydroxyethyl-aminobis(methylenephosphonic acid) (VI), 1-hydroxyethylidene-1,1-diphosphonic acid (VII), and 2-phosphonobutane-1,2,4-tricarboxylic acid (VIII) were characterized by ion trap mass spectrometry with el… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
13
2

Year Published

2006
2006
2013
2013

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 10 publications
(15 citation statements)
references
References 24 publications
0
13
2
Order By: Relevance
“…In a previous study, impurities of products I-V having the same hydrocarbon skeleton as the corresponding nominal compound, but with one or two -PO(OH) 2 groups substituted by protons, were found [22]. Impurities lacking one or two -CH 2 -PO(OH) 2 groups, and simultaneously lacking a -PO(OH) 2 group and a -CH 2 -PO(OH) 2 group, were also identified in the present work (see Tables 1-3).…”
Section: Infusion Spectra Of Products I-viiimentioning
confidence: 98%
See 3 more Smart Citations
“…In a previous study, impurities of products I-V having the same hydrocarbon skeleton as the corresponding nominal compound, but with one or two -PO(OH) 2 groups substituted by protons, were found [22]. Impurities lacking one or two -CH 2 -PO(OH) 2 groups, and simultaneously lacking a -PO(OH) 2 group and a -CH 2 -PO(OH) 2 group, were also identified in the present work (see Tables 1-3).…”
Section: Infusion Spectra Of Products I-viiimentioning
confidence: 98%
“…The identification procedures are next discussed. First, with the exception of VI, the infusion spectra of the APPs showed a characteristic peak pattern [22]. For each compound or group of isomers, the more intense peaks corresponded to a [M 2 nH 1 (n-1)Na] 2 series, where n ranged from 1 up to the number of -PO(OH) 2 groups.…”
Section: Infusion Spectra Of Products I-viiimentioning
confidence: 99%
See 2 more Smart Citations
“…Electrospray ionization mass spectrometry (ESI‐MS) is the most used technique for the study of non‐volatile small compounds and HMBPs have been exclusively analyzed in negative ion mode 8–11. Since the first MS fragmentation study12 only few mass spectrometric studies have been carried out on HMBPs.…”
mentioning
confidence: 99%