2017
DOI: 10.1016/j.jmmm.2016.07.024
|View full text |Cite
|
Sign up to set email alerts
|

Characterization of Ni ferrites powders prepared by plasma arc discharge process

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
5
1

Year Published

2017
2017
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 17 publications
(7 citation statements)
references
References 20 publications
1
5
1
Order By: Relevance
“…The M−H curve exhibits ferrimagnetic characteristics, with an s‐shaped pattern at lower fields and a linear variation at higher fields. In contrast to the theoretical value of 51.1 emu/g estimated by Safari et al ., [46] the measured Ms value is found to be 18.415 emu/g. The imperfections in ion distribution at tetrahedral and octahedral sites may lead to the deviations from Neel's two‐sublattice theory in the spinel lattice‘s net magnetization, and the presence of a canted structure could explain the lower experimental Ms values [47] .…”
Section: Resultscontrasting
confidence: 96%
“…The M−H curve exhibits ferrimagnetic characteristics, with an s‐shaped pattern at lower fields and a linear variation at higher fields. In contrast to the theoretical value of 51.1 emu/g estimated by Safari et al ., [46] the measured Ms value is found to be 18.415 emu/g. The imperfections in ion distribution at tetrahedral and octahedral sites may lead to the deviations from Neel's two‐sublattice theory in the spinel lattice‘s net magnetization, and the presence of a canted structure could explain the lower experimental Ms values [47] .…”
Section: Resultscontrasting
confidence: 96%
“…The results showed a decrease in lattice parameter values from 8.4404 Å (ZF) to 8.3857 Å (NZF) with Nickel content (x=0.6). This finding is in constancy with gradual substitution of Zn 2+ ions of larger ionic radius in ZF spinel by Ni 2+ ions with smaller ionic radius (0.83 Å vs 0.74 Å) in NZF nanoparticles [42][43][44][45][46]. The lattice parameter "a" is in good agreement with the standard JCPDS value of 8.441 Å (JCPDS No.…”
Section: Atomic Composition C19h10br4o5s λMax (Nm) 592supporting
confidence: 68%
“…The prepared bars cylindrical were used as an electrode in the vertical reaction chamber of an arc plasma reaction reactor. Additional details regarding the experimental setup and procedure have been reported elsewhere [25,27]. A Philips x-ray goniometer (PW-1840) equipped with Cukα 1 radiation (λ = 0.154 nm) was utilized to obtain the x-ray powder diffraction (XRD) pattern for the powders.…”
Section: Experimental Methodsmentioning
confidence: 99%
“…One of the main benefits of the PAD method, compared to other techniques, is that it provides a high reaction temperature as well as a relatively high cooling effect. Therefore, ultra-fine particles with a narrow particle size distribution can be easily and quickly obtained through this process [25][26][27].…”
Section: Introductionmentioning
confidence: 99%