1990
DOI: 10.1002/app.1990.070410746
|View full text |Cite
|
Sign up to set email alerts
|

Characterization of poly(tert‐butyl acrylate) by SEC

Abstract: In size exclusion chromatography (SEC) macromolecules are separated with respect to their hydrodynamic volume, which is proportional to a multiple of intrinsic viscosity and those of SEC chromatograms, the MHS constants K and a should be determined according to Weiss and Cohn-Ginsberg,' as demonstrated in this note for the case of poly( tert-butyl acrylate) (PtBA).

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
20
0
1

Year Published

1992
1992
2012
2012

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(25 citation statements)
references
References 4 publications
4
20
0
1
Order By: Relevance
“…(1) PtBA in THF [16] [η]=3.30×10 −3 M 0.80 (2) 1 H NMR spectra were recorded with a Bruker AM-250 spectrometer by using CDCl 3 as solvent at 25°C. The compositions of the diblocks and the final MTM triblocks were calculated from the relative intensity of the signals for the O-CH 3 protons in PMMA (3.6 ppm), and the -C(CH 3 ) 3 protons in PtBA (1.4 ppm).…”
Section: Discussionmentioning
confidence: 99%
“…(1) PtBA in THF [16] [η]=3.30×10 −3 M 0.80 (2) 1 H NMR spectra were recorded with a Bruker AM-250 spectrometer by using CDCl 3 as solvent at 25°C. The compositions of the diblocks and the final MTM triblocks were calculated from the relative intensity of the signals for the O-CH 3 protons in PMMA (3.6 ppm), and the -C(CH 3 ) 3 protons in PtBA (1.4 ppm).…”
Section: Discussionmentioning
confidence: 99%
“…The flow rate of THF was 1 ml/min, the system with separation range 10 3 -10 6 Da was calibrated with PMMA or polystyrene standards (PSS Germany). The eluograms of CDA macroinitiators were treated as CDA, those of copolymers with PMMA grafts as PMMA, eluograms of poly(CDA-g-St) as polystyrene [25] and eluograms of poly(CDA-g-BuA) as poly(2-ethylhexyl acrylate) [26]. It has to be noted that the calculated molecular weights of macroinitiators as well as those of copolymers are only apparent values.…”
Section: Analysis Of Polymersmentioning
confidence: 99%
“…In the case of the poly(alkyl acrylates) a clear discrepancy between the literature predicted curves44–52 is observed. Although many of the literature predicted curves intersect or closely describe the ESI‐MS measured molecular weight ratios, there is again great scatter among the literature data between 10 and 30%.…”
Section: Resultsmentioning
confidence: 72%