2013
DOI: 10.1371/journal.pone.0077289
|View full text |Cite
|
Sign up to set email alerts
|

Characterization of Polymeric Microneedle Arrays for Transdermal Drug Delivery

Abstract: Microfabrication of dissolvable, swellable, and biodegradable polymeric microneedle arrays (MNs) were extensively investigated based in a nano sensitive fabrication style known as micromilling that is then combined with conventional micromolding technique. The aim of this study was to describe the polymer selection, and optimize formulation compounding parameters for various polymeric MNs. Inverse replication of micromilled master MNs reproduced with polydimethylsiloxane (PDMS), where solid out of plane polyme… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
109
1

Year Published

2014
2014
2018
2018

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 135 publications
(116 citation statements)
references
References 42 publications
(45 reference statements)
3
109
1
Order By: Relevance
“…Axial compression tests involve subjecting the MNs to a force perpendicular to the base-plate [26]. They typically involve the use of a mechanical test station which records both displacement and force while the MNs are pushed against a hard metallic surface at a defined rate [41,42,43], Figure 3A.…”
Section: Axial Force Microneedle Mechanical Testsmentioning
confidence: 99%
See 2 more Smart Citations
“…Axial compression tests involve subjecting the MNs to a force perpendicular to the base-plate [26]. They typically involve the use of a mechanical test station which records both displacement and force while the MNs are pushed against a hard metallic surface at a defined rate [41,42,43], Figure 3A.…”
Section: Axial Force Microneedle Mechanical Testsmentioning
confidence: 99%
“…Transverse fracture force tests are therefore necessary to provide a more complete profile of the behaviour of MNs during application [42,43]. A mechanical test station is commonly used, where a transverse force (force applied parallel to the MN base-plate and normal to the microneedle y-axis) is applied at a defined point of the MN via a metal probe until the MN fractures.…”
Section: Transverse Force and Shear Strength Microneedle Mechanical Tmentioning
confidence: 99%
See 1 more Smart Citation
“…Biodegradable polymeric polylactic-co-glycolic acid (PLGA) MNs and dissolvable MNs, for instance, sodium alginate MNs are proved to create micro-holes in the skin layers without breaking, although the former one have more resistance and mechanical stability [49,50].…”
Section: Macromolecular Drugsmentioning
confidence: 99%
“…They developed adhesive patches, containing the molecules at defined loadings, were then attached to the upper base plates of hydrogel-forming MN, with the novel composite system termed as "integrated MN". However, according to the experimental details, for example, the delivery of insulin from the MN (with 600 μm height, 300 μm width at base, 50 Fig. 2 The design of PVP MN microneedles.…”
Section: Existing Problems Of Hydrogel Mnsmentioning
confidence: 99%