Characterization of polymers by size exclusion chromatography using multiple detection. Determination of the Mark-Houwink constants for Pullulan 100

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

1989
1989
2007
2007

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 2 publications
0
4
0
Order By: Relevance
“…Prior to analysis, the liquid samples of Venofundin and VitaHES were freeze dried and the resulting content of sodium chloride was taken into consideration accordingly. Mean Mw, Mw distribution, the Mark–Houwink constants K as well as free and esterified phosphate were determined as described by Sommermeyer 10 and Sommermeyer et al 11 …”
Section: Methodsmentioning
confidence: 99%
“…Prior to analysis, the liquid samples of Venofundin and VitaHES were freeze dried and the resulting content of sodium chloride was taken into consideration accordingly. Mean Mw, Mw distribution, the Mark–Houwink constants K as well as free and esterified phosphate were determined as described by Sommermeyer 10 and Sommermeyer et al 11 …”
Section: Methodsmentioning
confidence: 99%
“…39 We see that this ideal mode is described by equations (17) and (19). We have used this approach to venfy the universal calibration concept for several coil-like polymers, such as poly(ethy1 methacrylate), poly(viny1 acetate), and some statistical and block copolymers.…”
Section: Hydrodynamic Volume Calculation and Universal Calibration Comentioning
confidence: 97%
“…Using definition (1 1) and universal calibration hypothesis (19) we obtain from equations (21) -(23) for each slice i of a polymer distribution Usually, it is not an easy matter to find published v values for different wavelengths. Equation (24) allows calculating refractive index increments of each fraction of a polymer for one photometer, if the corresponding values for another with different wavelength are known and the universal calibration curve log Hst versus V is established.…”
Section: Hydrodynamic Volume Calculation and System Parametersmentioning
confidence: 99%
“…It was reported that the branched macromolecules led to deterioration of the service properties. An SEC system was outlined using multiple detection by LALLS and a concentration detector along with a differential viscometer (60). This combination of three detectors permits the determination of Mw, Mn, viscosity average molecular weight, and the Mark-Houwink constants.…”
Section: Gel Permeation and Size Exclusion Chromatography (Gpc Sec)mentioning
confidence: 99%