“…For Se 0 and Te 0 measurements, the pellets were washed with 1 M NaCl three times to remove Se( iv )/Te( iv ) and then treated with sonication (30 s sonication, 30 s pause, 30 min) in an ice bath; after that, the pellet was centrifuged (6000 rpm, 8 min), the supernatant was discarded, and the pellet was washed twice with 10 mL of NaCl (1 M), resuspended in 1 mL of Na 2 S (1 M, red solution for Se 0 measurement) or 1 mL of KOH (1 M, black solution for Te 0 measurement), and finally determined at 500 nm and 340 nm. 9 Se( iv ) and Te( iv ) concentrations were measured at 500 nm and 340 nm following the methods described by Arindam et al (2022) 16 and Mal et al (2017), 17 respectively. In addition, the electron transport system activity (ETSA) was detected according to a previously reported method.…”