Characterization of the PTB EUV reflectometry facility for large EUVL optical components

Abstract: The development of EUV lithography is critically based on the availability of suitable metrology equipment. To meet the requirements of industry, the Physikalisch-Technische Bundesanstalt has recently installed a new EUV reflectometer at the BESSY II electron storage ring. The EUV reflectometer is designed for at-wavelength metrology of full-size EUVL optics and allows samples with a maximum weight of 50 kg and a diameter of up to 550 mm to be investigated on the entire surface. Likewise, besides wavelength an… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
20
0

Year Published

2004
2004
2016
2016

Publication Types

Select...
6
2

Relationship

2
6

Authors

Journals

citations
Cited by 33 publications
(20 citation statements)
references
References 6 publications
0
20
0
Order By: Relevance
“…[67] with its degrees of freedom for the sample manipulator in red and for the detector in blue. The vacuum tank has a diameter of 2 m. Table 6 Compilation of PTB's beamlines and reflectometers used in the (V)UV [20,65,69,72], EUV [16,23,67,68,70,71], and X-ray spectral ranges [17,66]. The measured reflectance R of a sample is defined as:…”
Section: Detector-based Radiometrymentioning
confidence: 99%
See 1 more Smart Citation
“…[67] with its degrees of freedom for the sample manipulator in red and for the detector in blue. The vacuum tank has a diameter of 2 m. Table 6 Compilation of PTB's beamlines and reflectometers used in the (V)UV [20,65,69,72], EUV [16,23,67,68,70,71], and X-ray spectral ranges [17,66]. The measured reflectance R of a sample is defined as:…”
Section: Detector-based Radiometrymentioning
confidence: 99%
“…Currently, PTB operates three different reflectometer systems at BESSY II and the MLS [65][66][67]. As an example, Fig.…”
Section: Detector-based Radiometrymentioning
confidence: 99%
“…These specifications could, for the time being, only be verified using synchrotron radiation like, e.g. PTB at BESSY II [6][7][8] The total throughput for multiple site measurement, including reticle load, measure and unload, is required to be in the range of 3 to 6 masks/hour. No more than a few particles at 80 nm detection limit should be added per use.…”
Section: Demands On Euv-reflectometry For Mask Blanksmentioning
confidence: 99%
“…It is open to outside users. It is a significant improvement of the existing setup and addresses all requirements for quantitative reflectometry as known from other laboratories [25][26][27]:…”
Section: Introductionmentioning
confidence: 99%