2005
DOI: 10.1248/bpb.28.972
|View full text |Cite
|
Sign up to set email alerts
|

Characterization of Tumor Imaging with Microbubble-Based Ultrasound Contrast Agent, Sonazoid, in Rabbit Liver

Abstract: Ultrasonography (US) is useful for diagnosis of hepatic focal lesions, which is based on their distinctive echogenicities; the gray-scale morphologic features. To improve diagnostic ability of detection and characterization of tumors, contrast imaging has been used in diagnostic imaging, e.g. X-ray computed tomography (CT) or magnetic resonance imaging (MRI), but has not yet been popular in US since contrast agents for US are not at clinical satisfaction level. Intravenous US contrast agents available for clin… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
42
0

Year Published

2008
2008
2019
2019

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 63 publications
(42 citation statements)
references
References 27 publications
0
42
0
Order By: Relevance
“…The target lesions were scanned following injection in the arterial and Kupffer phases. The arterial phase of CEUS imaging was defined as that which occurred from 10-60 sec following the injection of Sonazoid™, and the Kupffer phase as that occurring 10 min following injection (10,12).…”
Section: Methodsmentioning
confidence: 99%
“…The target lesions were scanned following injection in the arterial and Kupffer phases. The arterial phase of CEUS imaging was defined as that which occurred from 10-60 sec following the injection of Sonazoid™, and the Kupffer phase as that occurring 10 min following injection (10,12).…”
Section: Methodsmentioning
confidence: 99%
“…the target lesions were scanned following injection in the arterial and Kupffer phases. The arterial phase of CEUS imaging was defined as that which occurred from 10 to 60 sec after injection of sonazoid, and the Kupffer phase as that occurring 10 min after injection (19). Fifteen frames/sec were usually used to scan for a low mechanical index (0.2-0.3).…”
Section: Methodsmentioning
confidence: 99%
“…Levovist (Schering AG, Berlin, Germany) is a first-generation contrast agent widely used to characterise focal liver lesions [8][9][10][11][12]. The advent of Sonazoid, a second-generation contrast agent (perfluorobutane; Diichi Sankyo, Tokyo, Japan), enables low mechanical index continuous real-time imaging and Kupffer imaging [13][14][15]. Therefore, contrast-enhanced ultrasound (CEUS) using Sonazoid could potentially offer high-quality, detailed vascular information and clearer Kupffer imaging.…”
mentioning