2016
DOI: 10.1097/icl.0000000000000230
|View full text |Cite
|
Sign up to set email alerts
|

Characterization of Upper Eyelid Tarsus and Lid Wiper Dimensions

Abstract: This work has demonstrated that there is a wide range in the dimensions of the upper tarsal plate in an urban UK population. No association was found between the upper tarsal dimensions and lid wiper staining. ImageJ was shown to be a repeatable method to measure the dimensions of the upper tarsal plate and upper lid wiper staining.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

4
11
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 15 publications
(15 citation statements)
references
References 36 publications
4
11
0
Order By: Relevance
“…The LWE area found in this study was very similar to the area of upper lid LWE reported with the previous methodology [19]. This semi-automatic image analysis system developed proved to be highly repeatable and hence a step towards truly automated objective grading of LWE.…”
Section: Discussionsupporting
confidence: 68%
See 2 more Smart Citations
“…The LWE area found in this study was very similar to the area of upper lid LWE reported with the previous methodology [19]. This semi-automatic image analysis system developed proved to be highly repeatable and hence a step towards truly automated objective grading of LWE.…”
Section: Discussionsupporting
confidence: 68%
“…This study built on the previously reported semi objective image analysis of the LWE [19], providing data on height, height relative to the lid margin width, and width as well as area. The LWE area found in this study was very similar to the area of upper lid LWE reported with the previous methodology [19].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…A more precise assessment of false negatives might be to quantify each participant's line of Marx staining area individually in order to establish a unique anatomic baseline for later comparison. Challenges arise in attempting such an investigation in the precise identification of the full extent of the line of Marx, given the expected variability in terms of width and location among subjects 16 Therefore, in line with previous studies using alternative semi-automated methodologies,- 9,17,18 it was considered clinically appropriate to use average to provide a basis to detect false negatives in the present study. Korb et al 6 reported the challenge of using paper impregnated strips to deliver adequate dye concentration and volume to uncover the full area of LWE staining.…”
Section: Discussionmentioning
confidence: 77%
“…15,16 The length of the lid margin has also been reported and measures 20.6 ± 1.9 mm. 17 Korb et al 8 used an assessment protocol that grades the horizontal length and width of the lid wiper staining (>10 mm is most severe). The inverted eyelid is curvilinear and mental estimations might make even approximate measurements very difficult.…”
Section: Introductionmentioning
confidence: 99%