2014
DOI: 10.1016/j.cej.2014.04.059
|View full text |Cite
|
Sign up to set email alerts
|

Characterizing the impact of MnO2 on the [47–49]efficiency of Fe0-based filtration systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

4
44
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 27 publications
(48 citation statements)
references
References 51 publications
4
44
0
Order By: Relevance
“…Tools to gain reliable design results from column studies were recently presented Allred 2012;Btatkeu-K et al 2013Btatkeu-K et al , 2014Miyajima and Noubactep 2015;Phukan 2015;Phukan et al 2015;Btatkeu-K. et al 2016;Phukan et al 2016). In this context, the differential adsorptive behavior of methylene blue onto sand and iron oxides (Mitchell et al 1955;Saha et al 2011) is used to follow the extent of in situ coating of sand in Fe 0 /sand filters.…”
Section: Designing Fe 0 Filters From Laboratory Datamentioning
confidence: 99%
See 1 more Smart Citation
“…Tools to gain reliable design results from column studies were recently presented Allred 2012;Btatkeu-K et al 2013Btatkeu-K et al , 2014Miyajima and Noubactep 2015;Phukan 2015;Phukan et al 2015;Btatkeu-K. et al 2016;Phukan et al 2016). In this context, the differential adsorptive behavior of methylene blue onto sand and iron oxides (Mitchell et al 1955;Saha et al 2011) is used to follow the extent of in situ coating of sand in Fe 0 /sand filters.…”
Section: Designing Fe 0 Filters From Laboratory Datamentioning
confidence: 99%
“…An Fe 0 /H 2 O system is the home state of iron oxides (oxide scale) with adsorptive affinities to Fe II species and contaminants (Mitchell et al 1955;Miyajima 2012;Btatkeu-K et al 2014;Phukan 2015;Phukan et al 2015;Btatkeu-K. et al 2016;Phukan et al 2016 (Yao et al 1971). This knowledge was established prior to the introduction of the Fe 0 remediation technology (Tseng et al 1984;James et al 1992).…”
Section: Designing Fe 0 Filters From Laboratory Datamentioning
confidence: 99%
“…Such experiments should not be stopped because contaminant breakthrough has occurred. In fact, the focus herein is on the efficiency of tested Fe 0 materials [69,71,72] and possibly characterizing the time to Fe 0 exhaustion (t 8 ). There is certainly an infinity of possibilities of experimental designs; the present effort will be limited to two approaches: (i) the sampling-port approach (in one column); (ii) the column-in-series approach.…”
Section: Ways To Reliable K Iron Valuesmentioning
confidence: 99%
“…Relevant tools include adding oxidizing agents to accelerate corrosion [58], increasing flow velocity [34] and using Fe 0 of smaller particle sizes and/or rapid small-scale column tests [65]. For the early phase of column operation, methylene blue (MB) discoloration has been proven a powerful indicator of reactivity [68][69][70][71][72][73][74]. Actually, the longest experiment with MB in this context lasted only for 4 months [69].…”
Section: (Section 2)mentioning
confidence: 99%
“…More than 200 Fe 0 -based reactive walls are installed worldwide and are performing well [10,36]. Some rules of thumb are now available to design efficient and sustainable Fe 0 filters, based on these and other achievements [37,38].…”
Section: Introductionmentioning
confidence: 99%