2021
DOI: 10.1016/j.clae.2020.12.017
|View full text |Cite
|
Sign up to set email alerts
|

Characterizing the surface properties of daily disposable contact lens materials

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(7 citation statements)
references
References 0 publications
0
7
0
Order By: Relevance
“…24 However, concerning the tear film stability, when the prelens tear film retracts (dewetting), these differences between different materials resulted less pronounced, as observed in vitro by analyzing the receding CA 24,25 and by in vitro techniques inspired by in vivo processes. 26,27 This could be ascribed to the rapid dehydration of the outer layer, which causes WG-CL properties to quickly transform into those of a low EWC SHy-CL, showing low dewetting time. Nonetheless, if the field is extended to other WG-CLs, the results are controversial: for example, some authors 27 reported a dewetting time four times longer for verofilcon A (SHy) than for other CLs.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…24 However, concerning the tear film stability, when the prelens tear film retracts (dewetting), these differences between different materials resulted less pronounced, as observed in vitro by analyzing the receding CA 24,25 and by in vitro techniques inspired by in vivo processes. 26,27 This could be ascribed to the rapid dehydration of the outer layer, which causes WG-CL properties to quickly transform into those of a low EWC SHy-CL, showing low dewetting time. Nonetheless, if the field is extended to other WG-CLs, the results are controversial: for example, some authors 27 reported a dewetting time four times longer for verofilcon A (SHy) than for other CLs.…”
Section: Discussionmentioning
confidence: 99%
“…26,27 This could be ascribed to the rapid dehydration of the outer layer, which causes WG-CL properties to quickly transform into those of a low EWC SHy-CL, showing low dewetting time. Nonetheless, if the field is extended to other WG-CLs, the results are controversial: for example, some authors 27 reported a dewetting time four times longer for verofilcon A (SHy) than for other CLs.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…8 One advancement in lens technology has been the creation of a new daily disposable silicone hydrogel lens material with water surface technology. The spherical lens design has good clinical acceptance, 9 fits well, 10 provides a more stable tear film compared to other lenses, 11,12 and has good comfort and vision. [13][14][15] The spherical lens design has recently been modified to incorporate toric prescriptions.…”
Section: Introductionmentioning
confidence: 99%