2023
DOI: 10.1016/j.ultrasmedbio.2022.09.019
|View full text |Cite
|
Sign up to set email alerts
|

Characterizing Viscoelastic Polyvinyl Alcohol Phantoms for Ultrasound Elastography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
18
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 11 publications
(18 citation statements)
references
References 41 publications
0
18
0
Order By: Relevance
“…To assess the effect of the cryoprotectant on the acoustic and mechanical properties of the phantoms, samples without the cryoprotectant were fabricated, comprising 8% w/v PVA (Elvanol 71–30, Kuraray America, Inc., Houston, USA), silicon carbide (SiC) acoustic scatterers (2% w/v, 600 mesh, Sarrah, India), and 90% v/v degassed, deionized water. , Samples with the cryoprotectant were made with the same concentration of PVA and SiC, except with 70% v/v degassed, deionized water and 20% v/v ethylene glycol-based cryoprotectant liquid (antifreeze coolant, Waxpol Industries Ltd., Ranchi, India).…”
Section: Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…To assess the effect of the cryoprotectant on the acoustic and mechanical properties of the phantoms, samples without the cryoprotectant were fabricated, comprising 8% w/v PVA (Elvanol 71–30, Kuraray America, Inc., Houston, USA), silicon carbide (SiC) acoustic scatterers (2% w/v, 600 mesh, Sarrah, India), and 90% v/v degassed, deionized water. , Samples with the cryoprotectant were made with the same concentration of PVA and SiC, except with 70% v/v degassed, deionized water and 20% v/v ethylene glycol-based cryoprotectant liquid (antifreeze coolant, Waxpol Industries Ltd., Ranchi, India).…”
Section: Methodsmentioning
confidence: 99%
“…The frequency-dependent attenuation spectra of the phantoms α( f ) were calculated as α ( f ) = 10 log 10 ( false| V ref ( f ) false| 2 false| V phantom ( f ) false| 2 ) / 2 h where f is the frequency and V ref and V phantom are the amplitudes of the reflected ultrasound signals without and with the phantom, respectively. The attenuation coefficient (dB/cm) was calculated by power-law regression . Longitudinal sound speeds and attenuation coefficients were measured from five independent locations in each phantom sample and five independent samples per phantom type.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations