2005
DOI: 10.1016/j.talanta.2005.02.001
|View full text |Cite
|
Sign up to set email alerts
|

Chelating ionophore based membrane sensors for copper(II) ions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
18
0
3

Year Published

2007
2007
2016
2016

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 50 publications
(21 citation statements)
references
References 22 publications
0
18
0
3
Order By: Relevance
“…These copper ion carriers include a thiaglutaric diamide derivative [10], small size thia crown ethers [11,12], pyridine- [13] and phenanthroline-based aza-thio crowns [14], calix [4]arens [15] Schiffs bases [16 -19], chelating ionophores [20,21], thiophosphoril-containing macrocycles [22] and macrocyclic diamides [23]. However most of these Cu(II)-selective membrane suffer interfering effects from Co 2þ , Ni 2þ , Cd 2þ , Hg 2þ and Ag þ ions as well as limited linear ranges.…”
Section: Introductionmentioning
confidence: 99%
“…These copper ion carriers include a thiaglutaric diamide derivative [10], small size thia crown ethers [11,12], pyridine- [13] and phenanthroline-based aza-thio crowns [14], calix [4]arens [15] Schiffs bases [16 -19], chelating ionophores [20,21], thiophosphoril-containing macrocycles [22] and macrocyclic diamides [23]. However most of these Cu(II)-selective membrane suffer interfering effects from Co 2þ , Ni 2þ , Cd 2þ , Hg 2þ and Ag þ ions as well as limited linear ranges.…”
Section: Introductionmentioning
confidence: 99%
“…ions using FT-SBA-15 nanoporous silica gel as matrices. Experimental results Hydrotris (3-isopropyl pyrazolyl)-methane 1.0 9 10 -6 -5.0 9 10 -2 2.0 9 10 -6 29.0 10 5.5 [32] Bis(acetylacetone)propylenediimine 1.0 9 10 -5 -5.0 9 10 -1 7.8 9 10 -6 30.0 10 3.3-7.0 [33] [2-Mercapto-5-(5-nitrofuran-2-yl)-1,3,4-thiadiazole]-gold-nanoparticle 7.9 9 10 -9 -7.9 9 10 -4 4.1 9 10 -9 31.0 5 2.5-7.0 [34] Bis[acetylacetonato] Cu(II) 2.0 9 10 -6 -1.0 9 10 -1 1.6 9 10 -6 29.3 9 2.6-6.0 [35] (3,4-Dihydro-4,4,6-trimethyl-2(1H)-pyrimidine thione) 9.77 9 10 -7 -7.6 9 10 -2 7.0 9 10 -7 30.0 45 2.0 [36] Etioporphyrin I dihydrobromide 1.28 9 10 -6 -1.28 9 10 -2 8.99 9 10 -7 30.2 5 4.5-8.5 [37] FT-SBA-15 1.0 9 10 -6 -1.0 9 10 -2 5.0 9 10 -7 29.6 44 3.9-6.6 This work indicated that the developed electrode exhibited a wide working concentration range (1.0 9 10 -6 -1.0 9 10 -2 -mol L -1 , low detection limit (5.0 9 10 -7 mol L -1 ) and fast response time (44 s). In addition, the detection limit, lifetime, selectivity and reproducibility of the developed electrode were acceptable.…”
Section: Resultsmentioning
confidence: 99%
“…A comparative study of the response characteristics of the previously reported papers on copper ion selective electrodes is shown in Table 3 [33][34][35][36][37][38]. The comparison indicates that the proposed electrode is superior to these reported Cu 2?…”
Section: Interference Studiesmentioning
confidence: 93%
“…Tables 5 and 6 compared the performance characteristics of the proposed sensors with those of the best previously reported Cu 2+ [25,[38][39][40][41][42] and Al 3+ [43][44][45][46][47] sensors. From the results in these tables, it can be concluded that, in many cases, the performances of the proposed electrodes show superior behavior if compared with previously reported electrodes.…”
Section: Comparison With the Previous Work And Applicabilitymentioning
confidence: 99%