2014
DOI: 10.1016/j.bbagen.2013.05.037
|View full text |Cite
|
Sign up to set email alerts
|

Chemical aspects of hydrogen sulfide measurements in physiological samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
258
0
1

Year Published

2014
2014
2024
2024

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 248 publications
(273 citation statements)
references
References 154 publications
3
258
0
1
Order By: Relevance
“…Hemoglobin from bovine blood (Sigma H2500), comprising mostly metHb, was used as received. Na2S • 9H2O (Aldrich, 431648) was used as H2S donor, which dissociates in solution and reacts with H + to yield HS − , H2S and a trace of S 2− [26]. We use the term 'sulfide' to encompass the total mixture of H2S, HS − and S 2− .…”
Section: Chemicalsmentioning
confidence: 99%
See 1 more Smart Citation
“…Hemoglobin from bovine blood (Sigma H2500), comprising mostly metHb, was used as received. Na2S • 9H2O (Aldrich, 431648) was used as H2S donor, which dissociates in solution and reacts with H + to yield HS − , H2S and a trace of S 2− [26]. We use the term 'sulfide' to encompass the total mixture of H2S, HS − and S 2− .…”
Section: Chemicalsmentioning
confidence: 99%
“…Na2S • 9H2O was washed in distilled H2O and then dissolved in H2O to give a stock solution of~100 mM, which was determined by the absorbance (ABS) at λmax 232 nm, ε = 7700. The concentration of polysulfides in this stock was <10 μM as judged by UV-VIS spectrophotometry [26]. This stock solution was always prepared fresh right before the experiment, kept in sealed vials with minimal headspace and used within 4 hours.…”
Section: Chemicalsmentioning
confidence: 99%
“…[16][17][18] The endogenous H 2 S can generate H 2 S n by reacting with ROS. [8][9][10][19][20][21] However, H 2 S n derivatives are proposed to be direct antioxidants against ROS in cells. 22,23 There is no doubt that H 2 S n possess their own bio-functions, but the evidence is limited owing to the lack of accurate and sensitive detection methods.…”
Section: Introductionmentioning
confidence: 99%
“…A more sensitive method is based on monobromobimane in which two monobromobimane molecules form the stable sulfide dibimane in the presence of H 2 S. Sulfide dibimane can be separated by reverse-phase chromatography and detected by a fluorescence detector. Now, fluorescent probes and sulfide selective electrodes are extensively used however, with different sensitivity and reliability (148). As yet, H 2 S measurements are difficult, with variable reliability, thereby complicating studies on the role of H 2 S and its use as therapeutic target in various diseases, including diabetes-associated vascular disease.…”
Section: Methods To Measure Gasotransmittersmentioning