Chemical disinfection of combined sewer overflow waters using performic acid or peracetic acids

Abstract: Highlights Performic and peracetic acid disinfection of combined sewer overflow was evaluated  Sewer overflow water for laboratory studies was made with diluted raw wastewater  The bathing water indicator E. coli was always easier to disinfect than Enterococcus  Peracetic acid required long contact time (2 ppm, 6 h) for efficient disinfection  Performic acid was short lived but potent, efficient disinfection by 2 ppm, 20 min Abstract We investigated the possibility of applying performic acid (PFA) and per… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

13
70
0
4

Year Published

2017
2017
2024
2024

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 75 publications
(87 citation statements)
references
References 18 publications
13
70
0
4
Order By: Relevance
“…Phosphate, and suspended solids were determined according to standard methods (APHA, 2012) and using Hach Lange test kits in the laboratory at Department of Environmental Engineering, Technical University of Denmark. PAA concentration was analyzed using the colorimetric method described by (Chhetri et al, 2014) based on selective oxidation of ABTS by PAA without interference from hydrogen peroxide.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…Phosphate, and suspended solids were determined according to standard methods (APHA, 2012) and using Hach Lange test kits in the laboratory at Department of Environmental Engineering, Technical University of Denmark. PAA concentration was analyzed using the colorimetric method described by (Chhetri et al, 2014) based on selective oxidation of ABTS by PAA without interference from hydrogen peroxide.…”
Section: Discussionmentioning
confidence: 99%
“…Residues of PAA were neutralized in laboratory experiments by adding 100 mg/L sodium thiosulphate to destroy PAA, followed by 50 mg/L catalase to destroy hydrogen peroxide (Wagner et al, 2002). E. coli was enumerated using Colilert-18 methods and Enterococcus were enumerated using the Enterolert methods from IDEXX (IDEXX laboratories, Maine, United States), as described by Chhetri et al (Chhetri et al, 2014). Heterotrophic microorganisms were enumerated by using direct plate count method as described in the standard methods (APHA, 2012).…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…They do not generate toxic by-products (Chhetri et al, 2014;Liberti and Notarnicola, 1999). Commercially available peroxycarboxylic acids are always available as a mixture of the peroxycarboxylic acids, hydrogen peroxide and corresponding carboxylic acid.…”
Section: Introductionmentioning
confidence: 99%