Search citation statements
Paper Sections
Citation Types
Year Published
Publication Types
Relationship
Authors
Journals
RationaleThe presence of volatile organic compounds (VOCs), notably diethyl phthalate, dimethyl phthalate, di‐n‐butyl phthalate, di(2‐ethylhexyl) phthalate, and similar compounds in soft drinks, raises significant concerns due to their known or potential adverse health effects. Monitoring these compounds is imperative to comprehend their implications on human health and the overall quality of soft drinks. Chemical ionization mass spectrometry (CI‐MS) techniques emerge as powerful tools for VOC quantification in soft drinks, offering fast analysis times, high detection sensitivity, real‐time analysis capabilities, and versatility across various scientific fields.MethodsAchieving absolute quantification of VOCs using proton transfer reaction mass spectrometry (PTR‐MS) presents challenges, with individual VOC calibration proving labor intensive. Theoretical approaches pioneered by Su and colleagues, including density functional theory (DFT), offer avenues for approximating VOC concentrations and understanding ion‐molecule reactions. Specifically, DFT method B3LYP/6–311++G(d, p) computes molecular parameters like dipole moment, polarizability, proton affinity, and ionization energy for large phthalate esters. Rate constants of ion‐molecule reactions are determined using the parametrized trajectory method under varying E/N and temperature conditions.ResultsThe analysis of computed parameters across seven complex molecules reveals notable findings. Bis(2‐methoxyethyl) phthalate, for instance, exhibits a superior dipole moment, suggesting intensified electrostatic interactions with ions and heightened rate constants. The increased proton affinity observed in certain molecules renders them suitable for specific ionization methods. Furthermore, enthalpy change and free energy computations affirm the reactivity of ions with phthalate esters, with distinct variations noted in rate constants based on dipole moment and polarizability.ConclusionsIn conclusion, the parametrized trajectory method, coupled with computational analysis of molecular parameters, offers a means to compute rate constants for ion‐molecule reactions, enabling determination of VOC concentrations in soft drinks without external calibration standards in PTR‐MS analyses. The observed variations in rate constants with temperature and reagent ions align with collision theory principles and existing literature findings, underscoring the utility of these approaches in VOC identification and quantification using PTR‐MS.
RationaleThe presence of volatile organic compounds (VOCs), notably diethyl phthalate, dimethyl phthalate, di‐n‐butyl phthalate, di(2‐ethylhexyl) phthalate, and similar compounds in soft drinks, raises significant concerns due to their known or potential adverse health effects. Monitoring these compounds is imperative to comprehend their implications on human health and the overall quality of soft drinks. Chemical ionization mass spectrometry (CI‐MS) techniques emerge as powerful tools for VOC quantification in soft drinks, offering fast analysis times, high detection sensitivity, real‐time analysis capabilities, and versatility across various scientific fields.MethodsAchieving absolute quantification of VOCs using proton transfer reaction mass spectrometry (PTR‐MS) presents challenges, with individual VOC calibration proving labor intensive. Theoretical approaches pioneered by Su and colleagues, including density functional theory (DFT), offer avenues for approximating VOC concentrations and understanding ion‐molecule reactions. Specifically, DFT method B3LYP/6–311++G(d, p) computes molecular parameters like dipole moment, polarizability, proton affinity, and ionization energy for large phthalate esters. Rate constants of ion‐molecule reactions are determined using the parametrized trajectory method under varying E/N and temperature conditions.ResultsThe analysis of computed parameters across seven complex molecules reveals notable findings. Bis(2‐methoxyethyl) phthalate, for instance, exhibits a superior dipole moment, suggesting intensified electrostatic interactions with ions and heightened rate constants. The increased proton affinity observed in certain molecules renders them suitable for specific ionization methods. Furthermore, enthalpy change and free energy computations affirm the reactivity of ions with phthalate esters, with distinct variations noted in rate constants based on dipole moment and polarizability.ConclusionsIn conclusion, the parametrized trajectory method, coupled with computational analysis of molecular parameters, offers a means to compute rate constants for ion‐molecule reactions, enabling determination of VOC concentrations in soft drinks without external calibration standards in PTR‐MS analyses. The observed variations in rate constants with temperature and reagent ions align with collision theory principles and existing literature findings, underscoring the utility of these approaches in VOC identification and quantification using PTR‐MS.
Abstract. Volatile organic compounds (VOCs) affect secondary pollutant formation via active chemistry. Proton-transfer-reaction mass spectrometry (PTR-MS) is one of the most important techniques to study the highly variable spatial and temporal characteristics of VOCs. The response of protonated, adduct, and fragmented ions in PTR-MS in changing instrument settings and varying relative humidity (RH) requires rigorous characterization. Herein, we present dedicatedly designed laboratory experiments conducted to investigate the response of these ions for 21 VOCs, including 12 oxygenated VOCs and 2 nitriles, using the recently developed Vocus PTR-MS. Our results show that the focusing ion–molecule reactor (FIMR) axial voltage increases sensitivity by 3 to 4 orders of magnitude but does not significantly change the fractions of protonated ions. Reducing the FIMR pressure, however, substantially increases fragmentation. Applying a high radio frequency (RF) amplitude radially to the FIMR can enhance sensitivity by 1 to 2 orders of magnitude without affecting the protonated ion fractions. The change in big segmented quadrupole (BSQ) amplitude mainly affects sensitivity and protonated ion fraction by modifying ion transmission. The relationship between sensitivity and proton-transfer reaction rate constant is complicated by the influences from both ion transmission and protonated ion fraction. The protonated ions of most VOCs studied (19 out of 21) show less than 15 % variations in sensitivity as RH increases from ∼ 5% to ∼ 85 %, except for some long-chain aldehydes which show a positive RH variation of up to 30 %. Our results suggest that the Vocus PTR-MS can reliably quantify the majority of VOCs under ambient conditions with varying RH. However, caution is advised for small oxygenates such as formaldehyde and methanol due to their low sensitivity and for long-chain aldehydes due to their slight RH dependence and fragmentation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.