2011
DOI: 10.1016/j.snb.2010.01.057
|View full text |Cite
|
Sign up to set email alerts
|

Chemical warfare agents simulants detection with an optimized SAW sensor array

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
63
1
3

Year Published

2011
2011
2024
2024

Publication Types

Select...
7
2
1

Relationship

1
9

Authors

Journals

citations
Cited by 87 publications
(68 citation statements)
references
References 15 publications
1
63
1
3
Order By: Relevance
“…The loaded Q-factor for the uncoated devices was ∼7500, while the obtained loaded Q-factors after protein depositions were greater than ∼5500. These results provided a suitable frequency stability for the electronic oscillators and were in line with those obtained with drop casting depositions (Di Pietrantonio et al, 2013) and with those achieved for optimised depositions of polymers (Matatagui et al, 2011;McGill et al, 1998). These findings support the feasibility of the LIFT for the deposition of proteins on SAW resonators.…”
Section: Obp Coating Assessment By Electrical Characterisation Of Sawsupporting
confidence: 86%
“…The loaded Q-factor for the uncoated devices was ∼7500, while the obtained loaded Q-factors after protein depositions were greater than ∼5500. These results provided a suitable frequency stability for the electronic oscillators and were in line with those obtained with drop casting depositions (Di Pietrantonio et al, 2013) and with those achieved for optimised depositions of polymers (Matatagui et al, 2011;McGill et al, 1998). These findings support the feasibility of the LIFT for the deposition of proteins on SAW resonators.…”
Section: Obp Coating Assessment By Electrical Characterisation Of Sawsupporting
confidence: 86%
“…Major directions of the advancement include (i) the optimization of sensing layer properties and coupling of the layers with analytes and piezoelectric substrates [91]; (ii) the control of the undesired effects and drifts that can arise from the devices itself, the environment, and the measurement system [91]; (iii) application for detecting and monitoring a range of gases, VOCs, and CWAs at different operating conditions [66,95]; and (iv) integration with electronics and improvement in signal analysis. Below, we discuss some of these advances.…”
Section: Advances In Saw-based Chemical Sensingmentioning
confidence: 99%
“…[16][17][18][19][20] Esses compostos têm como alvo principal a AChE. 17,21 Recentemente, um ataque na Síria (agosto de 2013) com o neurotóxico sarin alertou mais uma vez a opinião pública mundial e a comunidade científica para a utilização de armas químicas.…”
Section: Os Neurotóxicosunclassified